Operation

Starting the Engine

Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
NOTICE Failure to start and operate the unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Turn the fuel valve (A) to the "On" position.
A
3. Make sure idle control switch is in "Off" position.
4. Start engine according to instructions given in the
engine operator's manual.
WARNING Starter cord kickback (rapid retraction) can
result in bodily injury. Kickback will pull hand and
arm toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains
could result.
• When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
• NEVER start or stop engine with electrical devices plugged in
and turned on.
NOTICE If engine starts after 3 pulls, but fails to run for
more than 10 seconds, check for proper oil level in
crankcase. This unit may be equipped with a low oil
protection device. See engine operator's manual.
WARNING Contact with muffler area can result in
serious burns.
Exhaust heat/gases can ignite
combustibles, structures or damage
fuel tank causing a fire.
• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
• Keep at least 5 feet (152 cm) of clearance on all sides of
generator including overhead.
• It is a violation of California Public Resource Code, Section
4442, to use or operate the engine on any forest-covered,
brush-covered, or grass-covered land unless the exhaust
system is equipped with a spark arrester, as defined in Section
4442, maintained in effective working order. Other states or
federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer, or dealer
to obtain a spark arrester designed for the exhaust system
installed on this engine.
• Replacement parts must be the same and installed in the same
position as the original parts.

Connecting Electrical Loads

1. Let engine stabilize and warm up for a few minutes
after starting.
2. Plug in and turn on the desired 120 and/or 240 Volt
AC, single phase, 60 Hz electrical loads.
NOTICE
• DO NOT connect 240 Volt loads to the 120 Volt duplex
receptacle.
• DO NOT connect 3-phase loads to the generator.
• DO NOT connect 50 Hz loads to the generator.
• DO NOT OVERLOAD THE GENERATOR. See Don't
Overload Generator.
NOTICE Exceeding generators wattage/amperage capacity
can damage generator and/or electrical devices connected to
it.
• DO NOT exceed the generator's wattage/amperage capacity. See
Don't Overload Generator in the Operation section.
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
• Turn electrical loads OFF and disconnect from generator before
stopping generator.

Stopping the Engine

1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2. Move idle control switch to "Off" position.
3. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
4. Turn engine off according to instructions given in the
engine operator's manual.
5. Move fuel valve to "Off" position.
13