Diagnostics – Error Codes
Filling Timeout
This error code is triggered by feedback
from the pressure switch.
If the control does not receive a change
of pressure from the pressure switch
within 3 minutes, this code will be
entered into memory.
The washer will enter a pause state and
the user can attempt to restart the cycle.
This code will not be displayed to the
consumer.
This can be caused by water valves
turned off, pressure switch failure,
siphoning or problems with the pressure
switch wiring – hose or tub dome.