1.1.2 System Status LED Codes

The RFS7000 has four vertically-stacked LEDs on its front panel. Each of the switch's Gigabit Ethernet ports
have two status LEDs. These LEDs display two colors (green & amber), and three lit states (solid, blinking, and
off). The following tables describe the combinations of LED colors and states for the System Status LEDs and
the Gigabit Ethernet LEDs.

1.1.2.1 System Status LEDs

Start Up / POST (Primary System or Redundant System)
System Status 1 LED
Off
Green Blinking
Green Solid
Green Solid
Amber Blinking
Alternating Green Blinking
& Amber Blinking
NOTE When starting the switch, the Temperature Status LED will be Solid Amber. This is
normal behavior and does not indicate an error. At the completion of the start-up
process, the Temperature Status LED will switch to Solid Green.
Switch Status (Primary System)
System Status 1 LED
Off
Green Solid
Green Solid
Green Solid
System Status 2 LED
Off
Green Blinking
Green Blinking
Off
Off
Alternating Green Blinking
& Amber Blinking
System Status 2 LED
Off
Off
Green Solid
Amber Blinking
Event
Power off
Power On Self Test (POST) running
POST succeeded (Operating System Loading)
POST succeeded (Normal Operation)
POST Failure
Boot Up Error: Device has an invalid checksum
Event
Power off
No Redundancy Feature Enabled
Redundancy Feature Enabled
Actively Adopting Access Ports
No License to adopt Access Ports
or
No Country Code configured on the switch
or
License and Country Code configured, but no
APs adopted