I) There shall be adequate ventilation of the room when the rangehood is
used at the same time as appliances burning gas or other fuels
J) There is a risk of fire if cleaning is not carried out in accordance with the
instructions

INSTALLATION INSTRUCTIONS

Specialized personnel must carry out assembly and electrical connections.
• Electric Connection
The appliance has been manufactured as a class I, therefore earth cable is
necessary.
The connection to the mains is carried out as follows:
IEC227
L=live
Brown
N=neutral
Blue
E=earth
Green/Yellow
If not provided, connect a plug for the electrical load indicated on the
description label. Where a plug is provided, the cooker hood must be
installed in order that the plug is easily accessible.
An omnipolar switch with a minimum aperture of 3mm between contacts, in
line with the electrical load and local standards, must be placed between the
appliance and the network in the case of direct connection to the electrical
network.
• The minimum distance between the support surfaces of the cooking pots on
the cooker top and the lowest part of the cooker hood must be at least 65 cm.
If a connection tube composed of two parts is used, the upper part must be
placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor used to
circulate hot air or for evacuating fumes from other appliances generated by
other than an electrical source.
Before proceeding with the assembly operations, remove the anti-grease
filter(s) (Fig.5) so that the unit is easier to handle.
In the case of assembly of the appliance in the suction version prepare the
hole for evacuation of the air.
North America