Download Print this page

Troubleshooting - Omega K224 Installation And Operating Instructions Manual

Advertisement

E = LIGHT
• If your appliance does not have the INTENSIVE speed function, press key
A for two seconds and it will be activated for 15 minutes after which it will
return to the previously set speed. When the function is active the LED
flashes.
By pressing any key for the exclusion of the hood light the hood will return
immediately to its normal functioning.
The "automatic stop timer" delays stopping of the hood, which will
continue functioning for 15 minutes at the operating speed set at the
time this function is activated.

Troubleshooting

Problem
Hood doesn't work
Poor airflow
Motor running but no
air flow
Motor cuts after a
few minutes
Strong cooking smell
Oil
dripping
onto
stove
Whirring sound
THE MANUFACTURORY DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
Possible reason
No electric supply
Aluminum
grease
filters clogged
Charcoal
filters
clogged
Butterfly valve jammed Contact technician
High
temperature
safety device activated
The hood is installed
too near the cooking
stove
Charcoal
filters
not
installed
Oil cup missing or not
installed
Aluminum grease filter
saturated
Something in contact
with fan blade
Solution
Check the plug is connected
Check the main switch is turned on
Clean the filters and replace when
dry
Replace the charcoal filters
The kitchen is not sufficiently
ventilated
The hood must be least 65cm from
stove
In re-circulating mode, charcoal
filters must be installed
Remove
aluminum
replace oil cup
Wash the aluminum grease filters
Contact with technician
filter
and

Advertisement