ADEMCO VISTA 20HWSE Programming Form

ADEMCO VISTA 20HWSE Programming Form

2-partitioned security system

Advertisement

Quick Links

VISTA-20
SE
2-PARTITIONED
SECURITY SYSTEM
PROGRAMMING
FORM
®
Principal changes between the VISTA-20SE and
the former VISTA-20 are indicated by margin lines.
VISTA-20PRV4 8/97 (See Instructions N7526V4)
www.PDF-Zoo.com
firealarmresources.com

Advertisement

loading

Summary of Contents for ADEMCO VISTA 20HWSE

  • Page 1 VISTA-20 2-PARTITIONED SECURITY SYSTEM PROGRAMMING FORM ® Principal changes between the VISTA-20SE and the former VISTA-20 are indicated by margin lines. VISTA-20PRV4 8/97 (See Instructions N7526V4) www.PDF-Zoo.com firealarmresources.com...
  • Page 2 Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as a single partition only. Field Function Programmed Values ] = Default Value SYSTEM SETUP (*20–*29) * 20 INSTALLER CODE...
  • Page 3 * 48 REPORT FORMAT [7] [0] Primary Secondary 0 = 3+1, 4+1 ADEMCO L/S STANDARD 6 or undefined = 4+2 ADEMCO EXPRESS 1 = 3+1, 4+1 RADIONICS STANDARD 7 = ADEMCO CONTACT ID REPORTING 2 = 4+2 ADEMCO L/S STANDARD...
  • Page 4 * 49 SPLIT/DUAL REPORTING 0 = Disable (Backup report only) TO PRIMARY PHONE No. TO SECONDARY PHONE No. 1 = Alarms, Restore, Cancel Others 2 = All except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel A l l 4 = All except Open/Close, Test A l l 5 = A l l...
  • Page 5: Zone Description

    EXPANSION ZONES: Assign zone numbers (Zn) 10–17 to 4219/4229 Auxiliary Wired Loops A–H, if used. ENTER FOR ONLY RF zones can use zone numbers (Zn) 10–31 ZONE ZONE ZONE PART'N ALARM RPT CODE INPUT LEARNED DESCRIPTION TYPE (Hex) TYPEÊÊÊÊRF INPUT (Zn) (ZT) (RC)
  • Page 6 A "0" ( not "#+10") in both boxes will disable the report. 56): See procedure in instructions. With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report (entries in the...
  • Page 7 OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR 80, and Applicable only if Relays and/or Powerline Carrier Devicess are to be used. 80 OUTPUT DEVICES – This is an interactive menu mode. Fill in the required data on the worksheet on below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence.
  • Page 8: Special Messages

    ZONE LISTS FOR OUTPUT DEVICES – This is an interactive mode. Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Note: Record desired zone numbers below.