1714-Slot Z Drive Array Controller - Redundant Rom Checksum Error; 1715-Slot X Drive Array Controller - Memory Error(S) Occurred - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detected a checksum
failure but is unable to reprogram the backup ROM.
Action:
1. Upgrade the firmware using Options ROMPaq.
2. If the problem persists, replace the controller.
1714-Slot z Drive Array Controller - Redundant ROM Checksum
Error...
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation interrupted by power-cycle, or
flash ROM is failing. The controller has detected a ROM checksum error and
automatically switched to the backup ROM image.
Action: If this backup ROM image is a lower version than the originally running
image, upgrade controller firmware using Options ROMPaq.

1715-Slot x Drive Array Controller - Memory Error(s) Occurred

...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps: None
Possible Cause: The memory is beginning to fail.
Action: If this error persists, replace the controller.