1611-Redundant Fan Failure (Fan Zone System); 1612-Primary Power Supply Failure; 1615-Power Supply Configuration Error - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

256
HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide

1611-Redundant Fan Failure (Fan Zone System)

Audible Beeps: None
Possible Cause: A redundant fan is not spinning.
Action: Replace the failed fan.

1612-Primary Power Supply Failure

Audible Beeps: 2 short
Possible Cause: Primary power supply has failed.
Action: Replace power supply.

1615-Power Supply Configuration Error

Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A
moving bar is displayed, indicating that the system is waiting for another power
supply to be installed.
Action: Install the additional power supply.
1615-Power Supply Configuration Error
- A working power supply must be installed in Bay 1 for proper cooling.
- System Halted!
Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A
moving bar is displayed, indicating that the system is waiting for another power
supply to be installed.
Action: Install the additional power supply.