Less Than 75% Of Batteries At Sufficient Voltage Battery Pack X Below Reference Voltage; Logical Drive X Failed Due To Cache Error; Logical Drive X Status = Failed - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

Less Than 75% of Batteries at Sufficient Voltage Battery Pack X Below Reference
Voltage
Description: Battery pack on the array accelerator is below the required voltage
levels.
Action: Replace the array accelerator board if the batteries do not recharge
within 36 powered-on hours.

Logical Drive X Failed Due to Cache Error

Description: This logical drive failed due to a catastrophic cache error.
Action: Replace the array accelerator board and reconfigure using ACU.

Logical Drive X Status = Failed

Description: This status could be issued for several reasons:
Logical drive is configured for No Fault Tolerance, and one or more drives
failed.
Mirroring is enabled, and any two mirrored drives failed.
Data Guarding is enabled, and two or more drives failed.
Another configured logical drive is in the WRONG DRIVE REPLACED or
LOOSE CABLE DETECTED state.
Action: Check for drive failures, wrong drive replaced, or loose cable messages.
If a drive failure occurred, replace the failed drive or drives, and then restore the
data for this logical drive from the tape backup. Otherwise, follow the procedures
for correcting problems when an incorrect drive is replaced or a loose cable is
detected.
Troubleshooting
209

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml370 g4

Table of Contents