CLEANING & MAINTENANCE
Draning and Cleaning The Water Tank
Turn the power "off" and disconnect the air cooler from the power supply.
Move the unit to a location where it can be drained.
Remove the drain plug and allow the tank to empty(refer page 7., #14).
Refill the water tank up to the maximum level with clean water and drain
it completely.
Fill water tank and rinse at least 2-3 times before use.
After cleaning ensure that the drain plug is back in place.
• Plug into the power supply and turn on unit.
CLEANING THE HONEYCOMB COOLING MEDIA & CARBON FILTER
Turn off the unit, and unplug the power cord from wall
outlet.
Rotate the unit facing the back panel, and locate the Rear
Grill Removal Screws (refer page 7., #16). Remove the 4
screws with a screw driver.
Pull the rear grill panel upwards, until it is completely
removed.
The Honeycomb cooling media & carbon filter can now be
seen. Clean the carbon filter & honeycomb with clean cloth
to remove all the dust & dirt particles.
Once cleaning is finished, reassemble the unit as
described above.
Plug into the power supply and turn on unit.
The air cooler is now ready to be used. This cleaning process should be repeated monthly to
maintain the integrity of the unit and to remove particles filtered from the air.