On-screen message
Proc1 T-Trip
Proc2 T-Trip
ChipSet T-Trip
CPU1_DIMM U-Err
CPU2_DIMM U-Err
Processor1 IERR
Processor2 IERR
SMI timeout
WDT timeout
HDD 1 Fault
HDD 2 Fault
HDD 3 Fault
HDD 4 Fault
HDD 5 Fault
HDD 6 Fault
Sys Fan 1R Alarm
Sys Fan 2R Alarm
Sys Fan 3R Alarm
Sys Fan 4R Alarm
Sys Fan 5R Alarm
Sys Fan 6R Alarm
Sys Fan 7R Alarm
Sys Fan 1F Alarm
Sys Fan 2F Alarm
Sys Fan 3F Alarm
Sys Fan 4F Alarm
Sys Fan 5F Alarm
Sys Fan 6F Alarm
Sys Fan 7F Alarm
Description
The power was forcibly turned off
due to a CPU1 temperature
abnormality.
The power was forcibly turned off
due to a CPU2 temperature
abnormality.
The power was forcibly turned off
due to a chip set temperature
abnormality.
An unrecoverable error occurred
for a CPU1 DIMM.
An unrecoverable error occurred
for a CPU2 DIMM.
An internal CPU1 error (IERR)
occurred.
An internal CPU2 error (IERR)
occurred.
A timeout occurred while servicing
system management interrupts.
A watchdog timer timeout
occurred.
Operation was performed while
the hard disk drive had a failed
status (supported only when the
onboard RAID controller (LSI
Embedded MegaRAID
HDD 4 Fault to HDD 6 Fault only
apply to 2.5-inch hard disk drive
models.
A fan alarm was detected.
Contact your service
representative.
TM
) is used).
It is possible that a fan has failed
or is clogged up. Contact your
service representative and
request repairs.