With an appliance, the APPL indicator lights
with either an ON or an OFF indication. With
APPL set to OFF at a particular price, when the
price reaches that level, the appliance load
turns off, ignoring the program schedule. The
water indicator works identically to the appli-
ance indicator with one exception: when the
RSVP price is low the water indicator is always
on.
NOTE: Price Response programming does
not affect temperature, water, or
appliance holds.
For example, if you want your home heated to
72° during low rate, but are willing to allow the
temperature down as low as 70° during high
rate, your heat offset for rate H (high) is -2
(72° -2° = 70°). If you do not enter an offset,
the offset remains as shown in Table 2.
If you program an incorrect offset, press and
release the Clear key. This changes the offset
on the display to zero. The Clear key works for
all programmable rates.

Entering Price Response Programming

Price Response programming is very similar to
the other programming. One primary difference
is that you can program the temperature offsets
and water/appliance setting changes from the
same display. The same water and appliance
setting changes apply for both heating and
cooling. Therefore, they need only be set once.
Program them from either the heating or the
cooling offset display. The following program-
ming instructions—both heating and cooling—
detail this process.