T8600D, T8601D AND T8602D CHRONOTHERM
Installer Setup
Number (Press
Time
change)
Select
Not used
1
a
2
Fan operation
Not used
3
Heating cycle
4
rate
Not used
5 thru 11
System setting
12
adjustment
Adaptive
13
Intelligent
Recovery™
control
Degree
14
temperature
display
Not used
15
Clock format
16
Not used
17 and 18
Extended fan
19
operation in
a
heating
Extended fan
20
operation in
cooling
Not used
21 thru 23
Outdoor
24
temperature
display (select
models)
Not used
25 thru 29
Deadband
30
a
Number 2 must be set to 1 to extend fan operation.
68-0164—1
®
Table 6. Thermostat Installer Setup Options.
Factory-Setting
key to
Display
Description
0
Conventional
applications where
equipment controls fan
operation in heat mode
6
6—6 cph used for
conventional heat
1
Manual changeover
0
Adaptive Intelligent
Recovery™ control is
activated (system
starts early so setpoint
is reached by start of
program period)
0
Temperature is
displayed in °F
0
12-hour clock format
0
No extended fan
operation after the call
for heat ends
0
No extended fan
operation after the call
for cool ends
0
No outdoor
temperature is
displayed
3
Heating and cooling
setpoints can be set
no closer than 3°F
(1.5°C)
IV DELUXE PROGRAMMABLE THERMOSTATS
(Press
Display
1
Heat pump or electric heat
applications where thermostat
controls fan operation in heat
mode
1, 3 or 9
1—1 cph used for radiant floor
3—3 cph used for hot water
9—9 cph used for electric heat
0 or 2
0—Auto changeover
2—Fixed auto changeover
1
Conventional recovery (system
starts recovery at programmed
time)
1
Temperature is displayed in °C
1
24-hour clock format
1
Fan operation is extended 90
seconds after the call for heat
ends.
1
Fan operation is extended 90
seconds after the call for cool
ends.
1
Outdoor temperature is
displayed. Needs a
C7089B1000 Outdoor Sensor
to operate
4 thru 10
Heating and cooling setpoints
can be set no closer than the
chosen value:
8
Other Choices
or
key to change)
Description
heat, gravity system
systems or high efficiency
furnaces
systems
4—4°F (2°C)
5—5°F (2.5°C)
6—6°F (3°C)
7—7°F (3.5°C)
8—8°F (4°C)
9—9°F (4.5°C)
10—10°F (5°C)
Actual
Setting
(continued)