Download Print this page

Honeywell Switches and Sensors Brochure page 135

Honeywell industrial switches and sensors brochure

Advertisement

SA Series
The harsh duty SA pressure transducer has a water resistant, stainless steel
case for complete protection from harsh environments. Internal hermetic
sealing is used to provide measurement from absolute pressures (psia) or
pressures referenced to a sealed chamber (psis). Underwriters Laboratories
has approved the SA as a component in float and pressure-operated motor
controllers (File #E93356).
Approvals:
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Port style:
Output type:
Termination type:
SA WITH CABLE
3 conductor
color coded
shielded cable
0,91 m long (3 ft)
Excitation: Red
40,0
(1.56)
Signal: Wht
Common: Blk
Bare
(case shield)
OPTIONS
UL Approval
MEASUREMENT TYPE
PRESSURE RANGE
Absolute
0 psia to 15 psia
Absolute
0 psia to 25 psia
Absolute
0 psia to 50 psia
Absolute
0 psia to 100 psia
Gauge
0 psig to 15 psig
Sealed Gauge
0 psis to 100 psis
Sealed Gauge
0 psis to 200 psis
Sealed Gauge
0 psis to 500 psis
Sealed Gauge
0 psis to 3,000 psis
CE Approval
MEASUREMENT TYPE
PRESSURE RANGE
Absolute
0 psia to 25 psia
Absolute
0 psia to 50 psia
UL (*C1D products)
CE (*C1DE products)
9.0 Vdc to 24.0 Vdc
Amplified compensated
-55 °C to 105 °C (-48 °F to 221 °F)
-1 °C to 85 °C (30 °F to 185 °F)
1/8-27 NPT
1 Vdc to 6 Vdc
0,91 m (3 ft) 3-conductor shielded cable
1/8-27 NPT
3/8-24 UNF (optional ≥100 PSI)
19,0
10,0
(0.75)
(0.38)
48,0
(1.88)
1/2 Hex for 1/8-27 NPT port
9/16 Hex for 3/8-24 UNF port
REFERENCE
SA015PA1C1D
SA025PA1C1D
SA050PA1C1D
SA100PA1C1D
SA015PG1C1D
SA100PS1C1D
SA200PS1C1D
SA500PS1C1D
SA03KPS1C1D
REFERENCE
SA025PA1C1DE
SA050PA1C1DE
www.honeywell.com/sensing
SR Series
The Model SR is intended for OEMs requiring a small pressure sensor with
high pressure capability and superior corrosion resistance. Constructed of
brazen assembly of 300 series stainless steels, the SR can tolerate a wide
variety of corrosive medial without risk of leaking. The SR's design provide
high working pressures and high overload and burst pressures at no extra
cost.
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Port style:
Output type:
Termination type:
15,0 max.
(0.625)
7,6 max.
(0.30)
4,3 max.
(0.17)
19,0 / 18,95 18,5
(0.75)
(0.748 / 0.746)
A
O-RING GROOVE
PRESSURE RANGE (PSI)
P
e r
s
s
u
e r
R
a
n
g
e
P (
S
) I
B
o
e r
i D
. a
5 .
0
0
1
5
5 -
0
0
1 (
2
7 .
) 0
1
0
0
0
1 -
5
0
0
3 .
7
5
9 (
5 .
) 2
2
0
0
0
3 .
7
5
9 (
5 .
) 2
CAUTION: Contact with sensing surface at bottom of cavity will affect
accuracy and may cause damage. The O-ring groove on 2000 psi unit is
wider to accommodate a backup ring behind the O-ring.
All dimensions in inches (mm).
OPTIONS
MEASUREMENT TYPE
PRESSURE RANGE
Gauge
0 psig to 15 psig
Gauge
0 psig to 25 psig
Gauge
0 psig to 50 psig
Gauge
0 psig to 100 psig
Gauge
0 psig to 200 psig
Gauge
0 psig to 300 psig
Gauge
0 psig to 500 psig
Gauge
0 psig to 1,000 psig
Gauge
0 psig to 2,000 psig
PRESSURE SENSORS
5.0 Vdc
Unamplified compensated
-40 °C to 100 °C (-40 °F to 212 °F)
0 °C to 75 °C (32 °F to 167 °F)
Capsule
0 mV to 100 mV
4 - 22 AWG tinned Cu wires
4, 22 AWG
TINNED Cu SOLID WIRES
14,0 (0.55) LONG
a
+ Excitation
c
19,5 max.
- Excitation
(0.766)
d
b
- Signal
+ Signal
*
A
S
e
l a
n i
g
C
a
i v
y t
O
-
R
n i
g
D
e
p
h t
* *
D
e
p
h t
2
0 -
1
2
2 .
1
5 (
3 .
) 3
2 .
2
5 (
5 .
) 8
2
0 -
1
0
2 .
1
5 (
3 .
) 3
2 .
2
5 (
5 .
) 8
2
0 -
1
0
2 .
1
5 (
3 .
) 3
2 .
2
5 (
5 .
) 8
REFERENCE
SR015PGTB
SR025PGTB
SR050PGTB
SR100PGTB
SR200PGTB
SR300PGTB
SR500PGTB