Honeywell W8600F Owner's Manual page 21

Electronic air cleaner
Hide thumbs Also See for W8600F:
Table of Contents

Advertisement

Available languages

Available languages

5. Press the test button. A snapping sound
indicates the air cleaner is operating properly,
but the neon light is not working. If there is no
snapping sound, make sure the appropriate
fuse or circuit breaker is OK.
1. Cell and prefilter washing is due; wash as
The SERVICE
indicator on the
soon as possible.
W8600F activates
The FAULT
1. Make sure cell(s) are clean and dry.
indicator on the
W8600F activates
2. Check cells for visible damage.
BATTERY Indicator
1. Remove the cover from the W8600F, make
on the W8600F
sure the battery is firmly installed in holder.
activates
2. Replace the disc battery with type BR2032.
You smell ozone
Call your heating and air conditioning dealer.
and find it
objectionable
19
69-0756B—2

Advertisement

Table of Contents
loading

Table of Contents