Cisco UCS B440 M2 Spec Sheet

Blade server
Hide thumbs Also See for UCS B440 M2:

Advertisement

Cisco UCS B440 M2

Blade Server

C
S
ISCO
YSTEMS
170 W
T
D
.
EST
ASMAN
R
S
J
, CA, 95134
AN
OSE
.
.
WWW
CISCO
COM
P
H
UBLICATION
ISTORY
R
B.1
M
6, 2014
EV
AY
Spec Sheet

Advertisement

Table of Contents
loading

Summary of Contents for Cisco UCS B440 M2

  • Page 1: Blade Server

    Spec Sheet Cisco UCS B440 M2 Blade Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 6, 2014 CISCO...
  • Page 2: Table Of Contents

    Power Specifications ..........41 Cisco UCS B440 M2 Blade Server...
  • Page 3: Overview

    (HDDs) or solid-state drives (SSDs), 32 DIMM slots that support up to 1 terabyte (TB) of memory, and two dual-port mezzanine card connections for up to 40 Gbps of redundant I/O throughput. The Cisco UCS B440 M2 server is designed to power the most demanding enterprise applications. The UCS B440 M2 server is shown in...
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the front of the Cisco UCS B440 M2 Blade Server. Figure 2 Chassis Front View Hard drive bay 1 Right ejector thumbscrew Hard drive bay 2 Power button and LED...
  • Page 5: Base Server Standard Capabilities And Features

    CONFIGURING the SERVER on page Table 1 Capabilities and Features Capability/Feature Description Chassis The B440 M2 Blade Server mounts in a Cisco UCS 5100-series chassis Either 2 or 4 Intel® Xeon® E7-4800 or E7-8800 series processors Chipset Intel® 7510 chipset Memory 32 slots for registered DIMMs, up to 1 TB.
  • Page 6: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B440 M2 Server: STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 9 ■ STEP 4 CHOOSE HARD DISK DRIVES or SOLID-STATE DRIVES, page 13 ■...
  • Page 7: Step 1 Verify Base Sku

    Table 2 PID of the Base B440 M2 Server Product ID (PID) Description B440-BASE-M2 UCS B440 M2 Blade Server w/o CPU, memory, HDD, mezzanine The B440-BASE-M2 base server: Does not include CPUs, memory DIMMs, SSDs, HDDs, or mezzanine cards. ■...
  • Page 8: Step 2 Choose Cpu(S)

    Choose two identical CPUs from any one row in Table ■ (2) Four-CPU Configuration Choose four identical CPUs from any one row in Table ■ Caveats You must choose either two identical CPUs or four identical CPUs. ■ Cisco UCS B440 M2 Blade Server...
  • Page 9: Step 3 Choose Memory

    DIMMs. The maximum number of DIMMs that can be installed per CPU is 8 (4 DIMM kits). See Figure NOTE: Memory mirroring is supported and settable using the UCSM Service Profile “Memory RAS Configuration” setting. Cisco UCS B440 M2 Blade Server...
  • Page 10 CONFIGURING the SERVER Figure 3 B440 M2 Memory Organization Cisco UCS B440 M2 Blade Server...
  • Page 11 (1) Two UCS-MR-2X082RX-C and two UCS-MR-2X164RX-D DIMM kits per CPU, or (2) Two UCS-MR-2X082RX-C and two UCS-MR-2X324RX-C DIMM kits per CPU, or (3) Two UCS-MR-2X164RX-D and two UCS-MR-2X324RX-C DIMM kits per CPU. Cisco UCS B440 M2 Blade Server...
  • Page 12 Mixing DIMM speeds will cause the faster DIMMs to run at the speed of the slower DIMMs. ■ Your selected CPU(s) can have some affect on performance. The CPUs must be of the same ■ type. Cisco UCS B440 M2 Blade Server...
  • Page 13: Step 4 Choose Hard Disk Drives Or Solid-State Drives

    Select from 0 to 4 drives from Table ■ Caveats You can mix SAS/SATA drives, but not HDD/SSD drives. See STEP 5 CHOOSE RAID ■ CONFIGURATION, page 14 for available RAID configurations. You cannot mix HDDs and SSDs. ■ Cisco UCS B440 M2 Blade Server...
  • Page 14: Step 5 Choose Raid Configuration

    No RAID option will be effective if you have a mix of SAS and SATA drives. ■ No RAID option is possible if you have no drives. ■ You must have at least one drive installed in order to add an optional battery backup unit. ■ Cisco UCS B440 M2 Blade Server...
  • Page 15: Step 6 Choose Mezzanine Option Card(S)

    Table 9 Available PCIe Option Cards Product ID (PID) PID Description Virtual Interface Cards (VICs) UCS-VIC-M82-8P Cisco UCS VIC 1280 dual 40Gb capable Virtual Interface Card UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AC0002 Converged Network Adapters (CNA) Cisco UCS CNA M73KR-Q Qlogic Adapter...
  • Page 16 Emulex or QLogic adapter VIC 1280 2 x 10 Gb Figure 23 on page 39 Notes . . . 1. Do not mix Emulex and QLogic adapters 2. Do not mix Emulex and QLogic adapters Cisco UCS B440 M2 Blade Server...
  • Page 17: Step 7 Choose Operating System And Value-Added Software

    MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco Svc MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc SUSE SLES-SVR-2S-1G-1A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd...
  • Page 18 BMC BladeLogic Advanced Edition, 4 Cores, Support Required BMC-AE-6C BMC BladeLogic Advanced Edition, 6 Cores, Support Required BMC-AE-8C BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC-AE-10C BMC BladeLogic Standard Edition, 10 Cores, Support Required Cisco UCS B440 M2 Blade Server...
  • Page 19 VSG-VLEM-UCS-1 VSG License Paper Delivery (1 CPU) for bundles UCS Director CUIC-PHY-SERV-BM-U Cisco Cloupia Resource Lic - One Phy Server node bare metal CUIC-PHY-SERV-U Cisco Cloupia Resource Lic - One physical Server node CUIC-TERM Acceptance of Cisco Cloupia License Terms...
  • Page 20: Step 8 Choose Operating System Media Kit

    Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media Cisco UCS B440 M2 Blade Server...
  • Page 21: Step 9 Choose Service And Support Level

    SMARTnet for UCS For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
  • Page 22 For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
  • Page 23 CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. Table Table 15 Partner Support Service for UCS Service Product ID (PID)
  • Page 24 With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 25 UCS HW+DR UCWD5 8x5xNBD Onsite CON-UCWD5-B440M2 Retention For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS B440 M2 Blade Server...
  • Page 26: Order Optional Kvm Cable

    Product ID (PID) PID Description 37-1016-01 KVM Cable Figure 4 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB 2.0 connector (for a mouse and keyboard) Cisco UCS B440 M2 Blade Server...
  • Page 27: Supplemental Material

    SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL Motherboard A top view of the B440 M2 motherboard is shown in Figure Figure 5 B440 M2 Motherboard Cisco UCS B440 M2 Blade Server...
  • Page 28: Dimm And Cpu Layout

    Performance degradation can result from the following: ■ — Mixing DIMM sizes and densities within a pair is not allowed and both DIMMs in the pair will be logically removed from the memory array Cisco UCS B440 M2 Blade Server...
  • Page 29 Unevenly populating DIMMs between CPUs — Populating channels with an odd number of total ranks (for example, mixing single-rank and dual-rank DIMMs) — Using anything other than 4 or 8 DIMMs per CPU properly placed in the system Cisco UCS B440 M2 Blade Server...
  • Page 30: Network Connectivity

    This section explains how the UCS B440 M2 server connects to Fabric Interconnects using the network I/O adapters in the UCS B440 M2 blade server and the Fabric Extender modules in the UCS 5108 blade server chassis. The UCS B440 M2 server plugs into the front of the UCS 5108 blade server chassis. The Fabric Extender modules plug into the back of the UCS 5108 series blade server chassis.
  • Page 31 VIC 1280 Mezzanine adapter. This adapter plugs into either mezzanine slot and is capable of ■ 4x10Gb ports in the UCS B440 M2 server, depending on the Fabric Extender chosen (see Table 10 on page 16) and 256 PCIe devices.
  • Page 32 QLogic adapters). Ports A and B of each adapter connect to the Fabric Extenders, providing 10 Gbps per port, for a total of 40 Gbps throughput. Figure 10 Two Emulex or QLogic I/O Adapters to UCS 2204/2208XP Fabric Extender Cisco UCS B440 M2 Blade Server...
  • Page 33 Fabric Extender B. The result is 20 Gbps of bandwidth to each Fabric Extender. There is no adapter installed in adapter 1 slot. Figure 12 VIC 1280 to UCS 2204/2208XP Fabric Extender (no adapter in slot 1) Cisco UCS B440 M2 Blade Server...
  • Page 34 Fabric Extender B. Likewise, one port from the QLogic or Emulex adapter in slot 2 is also connected to each Fabric Extender. The result is 20 Gbps of bandwidth to each Fabric Extender. Figure 14 VIC 1280 and Emulex or QLogic adapter to UCS 2204/2208XP Fabric Extender Cisco UCS B440 M2 Blade Server...
  • Page 35: Connectivity Using The Cisco Ucs 2104Xp Fabric Extender

    Fabric Extender. The result is 20 Gbps of bandwidth to each Fabric Extender. Figure 15 VIC 1280 and Emulex or QLogic adapter to UCS 2204/2208XP Fabric Extender Connectivity using the Cisco UCS 2104XP Fabric Extender The options shown in Figure 16...
  • Page 36 1 slot. Ports A and B of the mezzanine adapter connect to the Fabric Extenders, providing 10 Gbps per port, for a total of 20 Gbps throughput. Figure 17 Emulex or QLogic I/O Adapter to UCS 2204/2208XP Fabric Extender (no slot 2 adapter) Cisco UCS B440 M2 Blade Server...
  • Page 37 Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender. There is no adapter installed in adapter 2 slot. Figure 19 VIC 1280 to UCS 2104XP Fabric Extender (no adapter in slot 2) Cisco UCS B440 M2 Blade Server...
  • Page 38 Extender A and one port form the other VIC 1280 is connected to Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender. <<is this a legal setup? No redundant path per adapter>> Figure 21 Two VIC 1280s to UCS 2104XP Fabric Extender Cisco UCS B440 M2 Blade Server...
  • Page 39 QLogic or Emulex adapter in slot 1 is connected to Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender. <<is this a legal setup? No redundant path per adapter>> Figure 23 VIC 1280 and Emulex or QLogic adapter to UCS 2104XP Fabric Extender Cisco UCS B440 M2 Blade Server...
  • Page 40: Technical Specifications

    1. The system weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items. Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/. Cisco UCS B440 M2 Blade Server...

Table of Contents