Service
Manual

The door lock unlocks the door

The programme unit requests door unlocking by
Fig.
applying 0 V on input X92 of the door lock
4
controller.
The following check is made prior to unlocking of
the door:
• No water in drum - input X93 from level
guard B2 is closed = 0 V
• Motor not engaged - input X94 from motor
controller U1 open = 5 V
• Drum not rotating - pulse frequency on input
X95 from rotation sensor B3 less than 0.4 Hz.
When the above conditions are met, the door
lock controller outputs an opening pulse on
output 96 to the door lock actuator/coil, which
then unlocks the door. Micro switches S4a and
S4b now interrupt the actuator/door lock and the
I/O card 1 relays lose all voltage to prevent the
motor from starting (interlock signal on motor
controller input X302). The drain and water
valves of the machine are now disabled and the
heater and motor cannot be switched on.
438 9145-61/06
04.10
29. Door and door lock
4
Door lock
control A31
X92
X93
X94
X96
X95
Motor
Level
control
X304
guard
U1
B2
M1
Rotation sensor B3
29
Programme
unit A1
I/O card 1
X4
A11
X10
X5
X302
Door lock
A41
5225
5