5.1.3
Cannot Access the Serial Console
Is the serial connection setting correct?
Make sure to set emulator application (Tera Term, etc.) connection as follows.
Conditions for Communication
Baud Rate
Data Length
Parity
Stop Bit
Are you using the correct conversion adapters and cables?
Check the conversion adapters (D-sub−RJ45, etc.) and cables being used
support serial console COM port. Optional conversion adapters are available.
Refer to
1.5.4 Serial Console Connection (page 12)
5.1.4
Cannot Operate the Device Locally
Are the video monitor, keyboard and mouse correctly connected?
Make sure that they are connected to the local port.
Refer to
1.5.2 Connection to the Host Server (page 10)
5.1.5
Cannot Access the Web page
Is the UTP cable shorter than specified limits?
The 10BASE-T and 100BASE-TX cable length must be shorter than 100m.
Make sure they are no longer than that.
Is the cable correctly connected?
Make sure that the Cat5 cable is connected to the Ethernet port.
Refer to
1.5.2 Connection to the Host Server (page 10)
If the network link is established, the LED in front of the device is on.
Is the network device power on?
Value
115200bps
8bit
none
1bit
5.1 Troubleshooting
SERVIS IP-KVM
145
1p Converter
User's Guide
5