Fujitsu Airstage UTY-VGGXZ1 Installation Manual
Fujitsu Airstage UTY-VGGXZ1 Installation Manual

Fujitsu Airstage UTY-VGGXZ1 Installation Manual

Network convertor
Hide thumbs Also See for Airstage UTY-VGGXZ1:

Advertisement

Quick Links

UTY-VGGXZ1
INSTALLATION MANUAL
NETWORK CONVERTOR
For authorized service personnel only.
INSTALLATIONSANLEITUNG
NETZWERKKONVERTER
Nur für autorisiertes Fachpersonal.
MANUEL D'INSTALLATION
Pour le personnel agréé uniquement.
MANUAL DE INSTALACIÓN
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
CONVERTITORE DI RETE
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
ΜΕΤΑΤΡΟΠΕΑΣ ΔΙΚΤΥΟΥ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
Apenas para técnicos autorizados.
РУКОВОДСТВО ПО УСТАНОВКЕ
Только для авторизованного обслуживающего персонала.
MONTAJ KILAVUZU
Yalnızca yetkili servis personeli için.
ADAPTATEUR RESEAU
CONVERTIDOR DE RED
CONVERSOR DE REDE
СЕТЕВОЙ КОНВЕРТОР
AÐ DÖNÜÞTÜRÜCÜ
PART NO. 9374707102-02

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu Airstage UTY-VGGXZ1

  • Page 1 INSTALLATION MANUAL NETWORK CONVERTOR For authorized service personnel only. INSTALLATIONSANLEITUNG NETZWERKKONVERTER Nur für autorisiertes Fachpersonal. MANUEL D’INSTALLATION ADAPTATEUR RESEAU Pour le personnel agréé uniquement. MANUAL DE INSTALACIÓN CONVERTIDOR DE RED Únicamente para personal de servicio autorizado. MANUALE DI INSTALLAZIONE CONVERTITORE DI RETE UTY-VGGXZ1 A uso esclusivo del personale tecnico autorizzato.
  • Page 2: Table Of Contents

    INSTALLATION MANUAL ▪ Area containing equipment that generates electromagnetic interfer- ence. It will cause the control system to malfunction, preventing the PART NO. 9374707102-02 unit from operating normally.Area that can cause combustible gas to NETWORK CONVERTOR leak, contains suspended carbon fi bers or fl ammable dust, or volatile infl...
  • Page 3: Electrical Requirement

    ELECTRICAL REQUIREMENT WIRING WARNING Size Wire type Remarks Before starting installation work, turn off the power of this unit and the 1.25 mm 1Ø AC208–240 V Maximum Power (16AWG) Type 60245 connection destination. Do not turn on the power again until installa- 50/60Hz, 2 Cable + supply IEC 57 or...
  • Page 4 5. 1. 2. Setting method when connecting a single split Transmission indoor unit cable Outdoor unit Remote controller cable Network convertor Indoor unit Wired remote Wireless remote Group remote controller controller controller [Example of connecting group remote controllers in a parallel ar- rangement] Transmission Cable to Transmission Cable to...
  • Page 5: Installing The Network Convertor

    indoor unit may enter the operation standby condition as described INSTALLING THE NETWORK CONVERTOR below. Ex. 1) If FAN setting is selected from the control unit, the LED on the indoor unit will fl ash and the unit will enter the operation standby WARNING condition.
  • Page 6: Connecting The Transmission Cables

    Setting method when connecting a single split indoor unit Dust proof bushing Knockout hole Power supply cable Cable tie Remote controller cables Cable Cable tie Transmission cable Earth Cable tie (Ground) Cable tie holder Earth (Ground) Tightening torque for installing cables to terminal block Cable tie holder 0.8 to 1.2 N •...
  • Page 7: Turning On The Power

    cannot be used more than once.   SETTING METHOD WHEN CONNECTING A SINGLE SPLIT Example: When SW110 is set to “1” and SW111 is set to “4”, the con- TYPE INDOOR UNIT vertor address will be “14”. CONNECTION OF REMOTE CONTROLLER CABLE Convertor address SW110 ...
  • Page 8: Circuit Board Setting

    WHEN CONNECTING TO THE EXCLUSIVE TERMINAL [DIP switch-SW103 <1, 2, 3, 4>] Signal BLOCK conversion type setting PATTERN1 —— When indoor unit packed together with the wired re- Connect the end of remote controller cable directly to the exclusive mote controllers shown in the table below is connected terminal block.
  • Page 9: Turning On The Power

    [DIP switch-SW107<1,2>,DIP switch-SW108<1,2>, DIP switch- When is displayed, the setting check mode ends. SW109<1,2>] Function setting → Turn on the power of each indoor unit and this unit again. If Set functions as shown in the following table. the power is not turned on, operation will not be normal even if returned to normal operation.