Adaptation To Different Types Of Gas - Zanussi ZBG 331 Instruction Booklet

Gas oven zbg 331
Hide thumbs Also See for ZBG 331:
Table of Contents

Advertisement

Adaptation to different types of gas

IMPORTANT
The replacement/conversion of the gas hob
should only be undertaken by qualified
personnel.
It is important to note that this model is designed for use
with natural gas G20 at a feeding pressure of 20 mbar
but can be converted for use with G30/G31, providing
the correct injectors are fitted. The gas rate is adjusted
to suit.
The oven burner does not need any primary
air regulation.
Replacement of gas oven
burner nozzle
To replace the gas oven nozzle, follow this procedure:
1. Remove the bottom plate of the oven cavity ("A");
2. Undo the two fixing screws ("C") which keep the
oven gas burner in place
3. Gently slide the oven gas burner off the injector
support ("D") and slowly move it to the left hand
side, taking care not to cause stress to the spark
candle connection wire ("E") and the thermocouple
("F") conductor;
3. With a socket spanner 7 unscrew and remove the
gas burner injector ("D"), and replace it with the
required one (see Table on this page);
4. Reassemble the burner following the same procedu-
re backwards.
5. Replace the Gas Type Sticker (it is located near the
gas connection ramp) with the one relevant to the
new gas type which is supplied with the injector kit.
Oven Gas Burner Data
GAS
INJECTOR
TYPE
MARK
1/100 mm
Natural Gas
114
(G20)
Liquid Gas
078
(G30/G31)
16
NOMINAL
NOMINAL GAS
GAS
FLOW IN
POWER
3
(kW)
m
/h
2,7
0,257
2,5
-
REDUCED
GAS
POWER
g/h
(kW)
-
1,0
182
1,0
BY-PASS
NOMINAL
NEEDLE
GAS
(1/100 mm)
PRESSURE
(mbar)
Reg.
20
52
30