GFCI RECEPTACLE
After starting the engine, check the GFCI for proper functioning by the following
test procedure.
Push blue TEST button, The red RESET button will pop out exposing the word
TRIP. Power is now off at the outlets protected by the GFCI, indicating that the
device is functioning properly.
If TRIP dose not appear when testing, do not use the generator. Call a
qualified electrician.
To restore power, push RESET button.
WARNING
If the RESET button pops out during operation, stop the generator
immediately and call a qualified electrician for checking generator and
the appliances.
FULL POWER SWITCH
Select the voltage using the FULL
POWER SWITCH in accordance with the
electrical appliance.
Refer to TABLE 2.
CAUTION
Change the FULL POWER SWITCH
after turning the
to "OFF".
NOTE :
Voltmeter always indicates the lower voltage whichever the FULL POWER
SWITCH is set.
Switch position
120V
120/240V
AC circuit breaker
Lower Voltage Receptacle
Activated full rated output
Activated half of rated output
1 2 0 V
TABLE 2
16
1 2 0 V
Higher Voltage Receptacle
N.A
Activated full rated output
2 4 0 V