BEFORE YOU BEGIN
Readthese instructions completely and carefully.
"
I M PO RTANT
-- Save these instructions
for local inspector's use.
" IMPORTANT
-- Observeall
governing codes and ordinances.
. Note toInstaller
- Be sureto leave these
instructions
withconsumer.
,
Note to consumer - Keep these
instructions for future reference.
,
Skill level - Installation of this appliance
requires a qualified installer or electrician.
,
Proper installation is the responsibility of the
installer.
* Product failure due to improper installation is
not covered under warranty.
FOR YOUR SAFETY:
Tip-Over
Hazard
A child or adult
can tip the range
and be killed.
Verify the anti-tip
bracket
has been
properly
installed
and engaged.
Ensure
the anti-tip
bracket
is re-engaged
when
the range
is moved.
Do not operate
the range
without
the anti-tip
bracket
in
place and engaged.
Failure
to follow
these
instructions
can result
in death
or
serious
burns
to children
or adults.
Anti-Tip Bracket
Kit Included
If you did not receive an anti-tip bracket with your purchase,
call 1.800.626.8774 to receive one at no cost. (In Canada,
call 1.800.561.3344.) For installation instructions of the bracket,
visit: www.GEAppliances.com
(In Canada, www.GEAppliances.ca,)
WARNING
-- Before
beginning t heinstallation,
switch
power off atservice p anel and lock
theservice d isconnecting
means to
prevent powerfrom beingswitched
on accidentally.
When theservice
disconnecting
means cannotbe
locked, securely fasten a prominent
warningdevice, suchas o tag, tothe
service panel.
MATERIALS YOU MAY NEED
TOOLS YOU WILL NEED
_
Drill with1/8" Bit
Tape Measure
Safety Glosses
Pliers
Adjustable Wrench
i/4" Nut Driver
Squeeze Connector
(ULListed40 AHP)
Level
5/16" Nut Driver
(For Conduit
4-Wire Cord 4' long OR
Tin Snips
Installations Only)
3-Wire Cord 4' long
PREPARE THE OPENING
(FOR INDOOR
USE ONLY)
See illustrations for all rough-in and spacing dimensions. The range may be placed with 0"
clearance (flush) at the back wall and side walls of the cabinet.
Unit will not mount flush
to counter when heights
ore lessthan 36".
SINGLE OVEN
I
L'-2_" On models with baking
or worming drawers,
lectrical outlet must not
be in this area.
Acceptable electrical
outlet area. Orient
electrical receptacle so
_71/'"the length is parallelto
floor.
Usea flush mount outlet
for double oven models.
45"
DOUBLE
OVEN
NOTE: Use a 4' power cord to prevent interference with
the storage drawer. Power cords 4_' to 6' long may
have to be dressed to allow for proper drawer closing.
MINIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring
and cabinets around the range can withstand the
heat (up to 200°F) generated by the range.
B. Allow ]0" minimum clearance between surface
units and bottom of unprotected wood or metal
cabinet, or allow a 24" minimum when bottom
of wood or metal cabinet is protected by no less
than 1/4" thick flame retardant millboard covered
with not less than No 28 MSG sheet metal, (.015'1,
.015" thick stainless steel, .024"
aluminum or .020" copper.
NOTE C
C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a
6" minimum spacing to surfaces less than lS" above the cooktop and adjacent
cabinet is recommended to reduce exposure to steam, grease splatter and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space
above the cooktop should be avoided. If cabinet storage space is to be provided above
the cooktop, the risk can be reduced by installing a range hood that projects at least 5" beyond
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 1]".
[_
ELECTRICAL
REQUIREMENTS
AWARNIN
G:
This appliance must be properly grounded.
_.WARN
I N G: All new constructions, mobile homes, recreational vehicles and installations where
local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.
AWARNI
N
G:To prevent fire or shock, do not use an extension cord with this appliance.
_I, WARN
IN G: To prevent shock, remove house fuse or open circuit breaker before beginning
installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified
electrician. After installation, have the electrician show you how to disconnect power from the range.
You must use a single-phase, 120/208 VACor 120/240 VAC,60 hertz electrical system. If you connect to
aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize
a 4-conductor connection to an electric range. When installing an electric range in new construction,
mobile home, recreational vehicle, or an area where local codes prohibit grounding through the neutral
conductor, refer to the section on four-conductor
branch circuit connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven
according to governing codes could result in a hazardous condition. If there are no local codes, your
oven must be wired and fused to meet the National Electrical Code, NFPA No. 70 - latest edition,
available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an individual,
properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker or time-delay fuse.
Use only a ]-conductor
or a 4-conductor UL-listed range cord. These cords may be provided with ring
terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not
recommended but if used, it should be marked for use with nominal 1.78" diamet_ r connection openings.
Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from
damaging the cable.
The rating plate is located on the oven frame or on the side of the drawer frame.
SINGLE OVEN
Rating plate
Ratin!
DOUBLE OVEN
POWER CORD AND CONDUIT INSTALLATION
Remove wire cover (on the back of range) by removing screws using a 1/4" nut driver. You can
access the terminal block by either removing a terminal block cover (on some models) or the
wire cover. Do not discard these screws.
Back of range
Back of range
c
-!-
i
°
i
Screw to
remove
terminal
block cover
_TerminaJ
block cover
@
For power cord and 1" conduit only, remove the
knockout ring (1%")located on bracket directly
below the terminal block. To remove the
knockout, use a pair of pliers to bend the
knockout ring away from the bracket and
twist until ring is removed.
Terminal block
(ap_
may vary)
ra
Screw to
remove
terminal
block cover
Terminal block cover
For power cord installations only (seethe
next step if using conduit), assemble the
strain relief in the hole. Insert the power
cord through the strain relief and tighten.
Allow enough slack to easily attach the
cord terminals to the terminal block. If tabs
are present at the end of the winged strain
relief, they can be removed for better fit.
NOTE: D o not install the power cord without
a strain relief.The strain relief bracket MUST
be installed before reinstallingthe rear range
wiring cover.
Knockout
ring in
bracket.
l
Knockoutring
___
removed
Strain relief
Power cord
Terminal
block
Bracket
r61
For ]/4" conduit installations only, purchase a squeeze connector matching the diameter of your
conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten.
Allow enough slack to easily attach the wires to the terminal block. NOTE:Do not install the conduit
without a squeeze connector. The squeeze connector MUST be installed before reinstalling the rear
range wiring cover.
Squeeze
/x_
_@
connector
Terminal block
Conduit
Bracket
PROCEEDTO STEP5 OR 6.
REMOVE PACKAGING
MATERIALS:
Failure t o remove packagingmaterials
couldresult i ndamage totheappliance. Remove all packingportsfrom oven,rocks, h eating
elementsand drawer.Also, remove protective film and labels on theouterdoor,cooktopand
control panel.
[_
3-WIRE INSTALLATION
_t_WARNI N G:
The neutral or ground wire of the power cord must be connected to the neutral
terminal located in the center of the terminal block and the ground strap must connect the neutral terminal
to the ground plate. The power leads must be connected to the lower left and the lower right terminals of the
terminal block.
DO NOT remove
the ground
strop
connection.
FOR POWER CORD INSTALLATION
A. Remove the ] lower terminal screws from the terminal block.
B. Insert the ] terminal screws through each power cord terminal ring and into the lower terminals of
the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower
position of the terminal block.
C. Tighten screws securely into the terminal block.
FOR CONDUIT
INSTALLATION
A. Loosen the ] lower terminal screws on the terminal block. Strip wire to exposed tip about 5/8" long.
B. Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On certain
models, the wire will need to be inserted through the ground strap opening and then into the bottom
center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal
block openings.
C. Tighten the screws until the wire is firmly secured (]5 to 50 inch-lbs.I. Do not over-tighten the screws.
NOTE: ALUMINUM WIRING:Aluminum building wire may be used but it must be rated for the correct
amperage and voltage.
Power Cord
Terminal block
(appearance
may vary)
Neutral terminal
Ground strap
Ground
plate
Conduit
Wire tips _--_i
__
I
Conduit
_1 -- I
Power cord
PROCEEDTO STEP 7.
31-10769-2J
08-11
GE
[_
4-WIRE INSTALLATION
_WARN
I NG:
The neutralwire of the supply circuit must be connected to the neutral terminal
located in the lower center of the terminal block.The power leads must be connected to the lower left and the
lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with
the ground plate and the green ground screw.
FOR POWER CORD INSTALLATION
A. Remove the ] lower terminal screws from the terminal block. Remove the ground screw and ground
plate and retain them. Cutand discardthe ground strap. DONOTDISCARD ANYSCREWS.
B. Insertthe one ground screw into the power cord ground wire terminal ring, through the ground plate
and into the frame of the range.
C. Insertthe ] terminal screws (removedearlier)through each power cord terminal ring and into the lower
terminals of the terminal block. Becertain that the center wire (white/neutral)is connected to the center lower
positionof the terminal block.Tightenscrews securely into the terminal block
FOR CONDUIT
INSTALLATION
A. Loosenthe 3 lower terminal screws on the terminal block. Remove the ground screw and ground plate and
retain them. Cut and discard the ground strap. DO NOTDISCARDANY SCREWS. Strip wire to exposed tip
about 5/8" long.
B. Insert the ground bore wire tip between the range frame and the ground plate (removed earlier)
and secure it in place with the ground screw (removed earlierl. Insert the bore wire (white/neutral)tip through
the bottom center of the terminal block opening. Insertthe two side bore wire tips into the lower left and the
lower right terminal block openings.
C. Tighten the screws until the wire is firmly secured 115to 50 inch-lbs.).Do not over-tighten the screws.
NOTE:ALUMINUM WIRING:Aluminum building wire may be used but it must be rated
for the correct amperage and voltage.
Before-Power Cord and Conduit
Ground _
_
\-,
strap
Neutral
terminal
After-Power
Cord
Terminal _
block
_
Ground _i
screw
;"
' ,7_x_3_
Neutral
oR
terminal
Ground plate
F
groundin
to
range)
After-Conduit
Terminal__
block
Wire ----"-_
/,"_
tips
_._
Ground screw
t_
_
round
plate
(grounding
_
torange)
r_
REPLACE THE WIRE COVER
Replace wire cover on range back by sliding its left edge under the retaining tabs and replace the
screws removed earlier. Make sure that no wires are pinched between cover and range back.
Back of range
II
Back of range
Screw to
If
remove
terminal
block cover
o
o71 'ver
r_
ANTI-TIP
DEVICE INSTALLATION
Tip-Over
Hazard
A child or adult can tip the range and be killed.
Verify the anti-tip
bracket
has been properly
installed
and engaged.
Ensure the anti-tip
bracket
is re-engaged
when the range
is moved.
Do not operate the range without
the anti-tip
bracket
in
place and engaged.
Failure to follow these instructions
can result in death or
serious
burns to children
or adults.
To reduce the
risk of tipping
the range, the
range must be
secured by a
properly installed
anti-tip bracket.
Seeinstallation
instructions
shipped with
the bracket
for complete
details before
attempting to
install.
To check if the bracket is installed and engaged properly, look underneath the range to see that the leveling
leg is engaged in the bracket. On some models, the storage drawer or kick panel can be removed for easier
inspection. If visual inspection is not possible, slide the range forward, confirm the anti-tip bracket is securely
attached to the floor or wall, and slide the range back so the leveling leg is under the anti-tip bracket. If the
range is pulled from the wall for any reason, always repeat this procedure to verify the range is properly
secured by the anti-tip bracket. Never completely remove the leveling legs or the range will not be secured to
the anti-tip device properly.
E_
LEVEL THE RANGE
AWARNIN
G:
Never completely remove the leveling leg
as the range will not be secured to the anti-tip device properly.
MODELS WITH STORAGEDRAWER OR KICK PANELS
r_
Plug in unit and slide into place. Pull drawer out until it stops.
r_
Lift front of drawer until the stops clear the guide. Remove the drawer.
FI
Install the oven shelves in the oven and position the range where
it will be installed.
b:op
Check for levelness by placing a spirit level on one of the oven shelves.
Take two readings-with
the level placed diagonally first
in one direction and then the other.
r_
The front leveling legs can be adjusted from the bottom
and the rear legs can be adjusted from the top or the bottom.
r_l
Use an adjustable wrench to adjust the leveling legs until the range is level.
[_1
LEVEL THE RANGE (CONT.}
r_
Position cord so that it does not interfere with drawer.
Place drawer rail on guides. Push the drawer in until it stops.
r_
Lift front of drawer and push in until the stops clear
the guides.
D
Lower the front of the drawer and push in until it closes.
MODELS WITH BAKING, WARMING DRAWERS OR DOUBLE OVEN
%
B3
E3
B3
EB
range
Plug in the unit.
Measure the height of your countertop at the rear of the opening.
Adjust two rear leveling legs so that the rear of cooktop is at the same height as the counter.
Slide unit into place.
Install oven shelves in the oven and position the range where it will be installed.
Check for levelness by placing a spirit level on one of the oven shelves.
Take two readings-with
the level placed diagonally first in one direction
and then the other.
Adjust front leveling legs until the range is level.
r"-'-i
FINAL INSTALLATION
CHECKLIST
Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
Be sure power is in service to the building.
Check that all packing materials and tope hove been removed. This will include tope on metal panel under
control knobs {if applicable), adhesive tope, wire ties, cardboard and protective plastic. Failure to remove
these materials could result in damage to the appliance once the appliance has been turned on and
surfaces hove heated.
Check that the door and drawer are parallel to each other and that both operate smoothly. If they
do not, see the Owner's Hanual for proper replacement.
Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket
is securely installed.
OPERATION CHECKLIST
Turn on one of the surface units to observe that the element glows within 60 seconds. Turn the unit
off when glow is detected. If the glow is not detected within the time limit, recheck the range wiring
connections. If change is required, retest again. If no change is required, have building wiring checked for
proper connections and voltage.
Check that the Clock (on models so equipped) display is energized. If a series of horizontal red
lines appear in the display, disconnect power immediately. Recheck the range wiring connections.
If change is made to connections, retest again. If no change is required, have building wiring checked for
proper connections and voltage. It is recommended that the clock be changed if the red lines appear.
Be sure all range controls are in the OFFposition before leaving the range.

Advertisement

loading

Summary of Contents for GE PHS925ST1SS

  • Page 1 I N G: All new constructions, mobile homes, recreational vehicles and installations where Questions? wire cover. Do not discard these screws. Calt 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord. Back of range Back of range In Canada, calt 1.800.561.3344 or visit www.GEAppliances.ca...
  • Page 2 _Preguntas? 2Y," zl//' 119,1 cm} de tuercas de 1/4". Usted puede acceder el bloque terminal quitando la tapa del bloque Llamada L8OO.GE.CARES(1.800.432.2737) o visita www.GEAppliances.com " "30" (76,2 cm) _, ADVERTENCIA: Todas los construcciones nuevas, casas rodantes, veh[culos recreativos e terminal (en algunos modelos) o la tapa de los cables.