D-Link 1000BASE-TX User Manual
D-Link 1000BASE-TX User Manual

D-Link 1000BASE-TX User Manual

1000base-tx to 1000base-sx/lx media converter
Hide thumbs Also See for 1000BASE-TX:

Advertisement

Quick Links

1000BASE-TX to
1000BASE-SX/LX

Media Converter

User's Guide
Rev. 01 (JUN. 2002)
Printed In Taiwan
RECYCLABLE

Advertisement

Table of Contents
loading

Summary of Contents for D-Link 1000BASE-TX

  • Page 1: Media Converter

    1000BASE-TX to 1000BASE-SX/LX Media Converter User’s Guide Rev. 01 (JUN. 2002) Printed In Taiwan RECYCLABLE...
  • Page 2 TABLE O N T E N T S TABLE OF CONTENTS ......2 INTR ODUCTION ........3 ........3 BOUT EDIA ONVERTER PRODUCT FEATURES ......3 INSTALLATION ........3 ..... 3 ELECTING A ITE FOR THE QUIPMENT ..........4 ONNECTING TO OWER ...........
  • Page 3: About Media Converter

    NTRODUCTION Thank you for choosing the 1000Base Gigabit Ethernet Media Converter, The Converter introduced here provides one channel media conversion between 1000BASE-TX and 1000BASE-LX/SX. About Media Converter Media Converter is a network technology specified by IEEE 802.3ab and IEEE 802.3z 1000BASE-TX/FX standards.
  • Page 4: Connecting To Power

    The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 degrees Celsius). The relative humidity should be less than 90 percent, non-condensing. Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.
  • Page 5: Led Indicator

    First, install the converter onto a carrier supplied with the chassis: Step 1- Unscrew and pull out the media converter board. Step 2- Plug in the media board to any of the vacant slot. Step 3- Fit the converter onto the carrier and use the screw to secure it.
  • Page 6: Link Pass Through Function

    Link Pass Through Function LLCF (Link Loss Carry Forward) When a device connected to the converter and the TP line loss the link, the converter’s fiber will disconnect the link of transmit, so that the other ends will know that there is a linkage error on this end.
  • Page 7: Specifications

    When the switch was turned to “On”, it means that the LLR was enabled and “Off” for disabled. Note: When using two converters at the same time, then only one converter need to enable the LLR function. PECIFICATIONS Standards: IEEE802.3ab 1000BASE-TX IEEE802.3z 1000BASE-SX/LX Data Transfer 1488000pps for 1000Mbps Rate:...

This manual is also suitable for:

1000base-sx1000base-lx

Table of Contents