b)
If the host bus adapter connector is of the "SC" type
Use the optional FC conversion cable (NF9310-SJ10E). The cable has different-size
connectors at the ends. Push the smaller connector into the FC connector (HPx) for the host
bus adapter of either controller (CONT0 or CONT1) until a click is heard.
Pushing any connector excessively may damage the tip decreasing the
optical intensity, which will then cause a malfunction to occur.
Connect the other end of the FC conversion cable to either of the FC switch via the relay
connector provided with the FC conversion cable and optional FC cable (SC-SC cable:
NF9310-SJ0xE). Push the connector so that it clicks securely. The connector at an end of the
FC cable (SC-SC cable: NF9310-SJ0xE) is the same as that at the other end. Either of the
connectors may be connected to the relay connector.
Similarly, connect the other controller to the FC switch.
Connect the connector at one end of the SC-SC cable to the connector for connecting the host
bus adapter installed in the host system, and the connector at the other end to the above FC
switch.
Be sure to push the connectors until a click is heard.
Subsequently, connect the FC connector (HPx) for the host bus adapter, which is on each
controller, to the other FC switch via the FC conversion cable and SC-SC cable.
Also connect the other host bus adapter in the host system to the FC switch via the SC-SC
cable.