7. Bend thecopper tubing tomeet thewater l ine inlet w hich is
located o ntheback oftheicemaker cabinet asshown,
REAR VIEW
A
B
8=
A. Drain hose (drain pump models only)
B. Vent hose (drain pump models only)
C. Water supply line
Thread the nut onto the coupling on the end of the copper
tubing. Tighten the nut by hand. Then tighten it with a wrench
two more turns. Do not overtighten.
A
B
C
D
E
F
A. Line to ice maker
D. Coupling (purchased)
B. Nut (purchased)
E. Ferrule (purchased)
C. Ferrule (purchased)
F Nut (purchased)
Connecting the drain
Gravity drain system
Connect the ice maker drain to your drain in accordance with all
state and local codes and ordinances.
If the ice maker is
provided with a gravity drain system, follow these guidelines
when installing drain lines. This will prevent water from flowing
back into the ice maker storage bin and potentially flowing onto
the floor causing water damage.
Drain lines must have a minimum of %" (15,88 mm) inside
diameter.
Drain lines must have a 1" drop per 48" (2.54 cm drop per
122 cm) of run or 1/4"drop per 12" (6.35 mm per 30.48 cm)
and must not have low points where water can settle.
The floor drains must be large enough to accommodate
drainage from all drains.
The ideal installation has a standpipe with a 11/2"(3.81 cm) to
2" (5.08 cm) PVC drain reducer installed directly below the
outlet of the drain tube as shown. You must maintain a
1" (2.54 cm) air gap between the drain pump hose and the
standpipe.
It may be desirable to insulate the drain line thoroughly up to
the drain inlet,
After ensuring that the drain system is adequate, follow these
steps to properly place the ice maker:
1. Plug in ice maker or reconnect power.
2. Recheck the ice maker to be sure that it is level. See
"Leveling."
3. Push the ice maker into position so that the ice maker drain
tube is positioned over the PVC drain reducer.
SIDE VIEW
9=
Remove the two screws in the lower access panel and the
two screws in the base grille area of the front panel support.
Pull forward to remove the lower access panel.
NOTE: To prevent rattling, be sure the copper tubing does
not touch the cabinet's side wall or other parts inside the
cabinet,
FRONT VIEW
L
J
123/16"
_
(30.9 cm)
A
I
51V16
.
(14.5 cm)
#
7s/16"
(18,9 cm)
5%"
(14.3cm)
A. Water pan drain
B. Water valve
10. Turn shutoff valve ON.
11. Check for leaks. Tighten any connections (including
connections
at the valve) or nuts that leak.
12. Replace the lower access panel and screws,
23"
C
(58.4 cm)
D
2" - 1V2"
(5 cm - 3.8 cm)
A. Drain hose
B. !" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the 3/4" (1.91 cm) panel on the door:
4. If it is required by your local sanitation code, seal the cabinet
to the floor with an approved caulking compound
after all
water and electrical connections
have been made.
Drain pump system (on some models}
Connect the ice maker drain to your drain in accordance
with the
International Plumbing Code and any local codes and
ordinances.
NOTE: If the drain hose becomes twisted and water cannot
drain, your ice maker will not work.