Commercial
Thermostats
Use
Reset type
Housing material
Functional property
Amperage
Operating temperature range
Environmental exposure range
Contacts
Approvals
Commercial
Thermostats
Use
Reset type
Housing material
Functional property
Amperage
Operating temperature range
Environmental exposure range
Contacts
Approvals
2450RC Series
high current
automatic
ceramic
open or close on rise
15 A/10 A
0 °C to 260 °C [32 °F to 500 °F]
-20 °C to 287 °C [0 °F to 550 °F]
silver/nickel alloy
UL, CSA, VDE
2455R Series
high current
automatic
phenolic
open or close on rise
15 A/10 A
0 °C to 150 °C [32 °F to 302 °F]
-18 °C to 177 °C [0 °F to 350 °F]
silver/nickel alloy
UL, CSA, VDE
2450RCG Series
low voltage
automatic
ceramic
open or close on rise
0.5 A
0 °C to 260 °C [32 °F to 500 °F]
-20 °C to 287 °C [0 °F to 550 °F]
WE-1 gold alloy cross point
UL, CSA, VDE
2455RA Series
heat detection
automatic
phenolic, epoxy seal cap and terminals
close on rise
3 A
47 °C to 107 °C [117 °F to 225 °F]
0 °C to 150 °C [32 °F to 302 °F]
WE-1 gold alloy cross point
UL
2450RG Series
low voltage
automatic
phenolic
open or close on rise
0.5 A
0 °C to 150 °C [32 °F to 302 °F]
-18 °C to 177 °C [0 °F to 350 °F]
WE-1 gold alloy cross point
UL, CSA
2455RVB Series
high current
automatic
ceramic, epoxy overmold
open or close on rise
15 A/10 A
-12 °C to 105 °C [10 °F to 250 °F]
-18 °C to 121 °C [0 °F to 250 °F]
silver/nickel alloy
UL, CSA, VDE