Customer Responsibilities; Product Specincations'_ - Kenmore 153.330401 Owner's Manual

40, 50 & 75 gal. highaltitude, for potable water heating only not suitablefor space heating, not for use in mobile homes
Hide thumbs Also See for Kenmore 153.330401:
Table of Contents

Advertisement

Customer
Responsibilities
Thank You
for purchasinga
Sears water heater.
°
Properly
installed
and maintained,
it should
give you years of
trou'blefree
service. If you should decide that you want the new
water heater professionally
installed by Sears call the local Sears
Service Center or any Sears store. They will arrange for prompt,
quality installation
by Sears authorized contractors.
Abbreviations
Found In This Instruction
Manual
A.G.A. - American
Gas Association
o
A.N.S.I. - American National
Standards
Institute
N.EP.A. - National
Fire Protection
Agency
A WARNING
This gas-firod water beater is design certified by the
American Gas Association Laboratories under American
National Standards for Gas Water Heaters. The installa-
tion must conform with this manual, LocalCodes and with
the latest edition of the National Fuel Gas Code, ANSI
/.223.1.
This publicationis available from your local g.ove, rnment or
public library, gas company, or by wr,tmg
NFPA,
Batterymarch Park, Quincy,MA 02269.
• Read the "Safety Precautions" section, pages 2 through 4 of
this manual first and then the entire manual carefully. If you
don't follow the safety rules, the water heater will not operate
properly. It could cause DEATH, SERIOUS
BODILY
INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera-
tion, and maintenance of the gas-fired water heater. It also
contains warnings through out the manual that you must read
and be aware of. All warnings and all instructions are essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, READ
THE ENTIRE MANUAL BEFORE ATTEMPTING TO
INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; gas company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition of the National
Fuel Gas code, ANSI Z223.1, also referredto as NFPA 54.
This publication is available from your local government or
public library
or gas company
or by writing NFPA,
Batterymarch Park,Quincy,/viA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefillly plan the place where you aregoing to put the water
heater. Correct combustion, vent action, and vent pipe instal-
lation are very important in preventing death from possible
carbon monoxide poisoning and fires.
Examine the location to ensure the water hea_r complies with
the _Facts to Consider about the Location section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce-
dures. Instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Product Specifications
MODEL
NUMBER
TANK
CAPACITY
IN GALLONS
TYPE
OF
GAS
gT.U.
RATE
RECOVERy RA1_
GAI_ PER HOUR
OgO'F RISE
153.330401
40
NATURAL
40,000
46.0
153.330451
40
NATURAL
40,000
46.0
153.330501
50
NATURAL
40,000
46.0
153.330551
50
NATURAL
40,000
46.0
153.330701
75
NATURAL
55,000
59.2
153.330751
75
NATURAL
55,000
59.2
MINIMUM
VENT
PIPE
3" or4"
3" or4"
3" or 4"
3" or 4"
4"
4"
DIMENSIONS IN INCHES
HEIGHTTO
DIAMETER JACKETTOP
18"
60"
18"
60"
20"
59½"
20"
59½"
24"
60"
24"
60"

Hide quick links: