Strange Sounds; Operational Conditions; Smelly Water; Air" In Hot Water Faucets - Kenmore 153.330401 Owner's Manual

40, 50 & 75 gal. highaltitude, for potable water heating only not suitablefor space heating, not for use in mobile homes
Hide thumbs Also See for Kenmore 153.330401:
Table of Contents

Advertisement

Troubleshooting
Guide (cont'd)
Operational
Conditions
HOT
COLD
WATER H EATER
O)
• COLD WATER
PRESSURE
rINLET FITTING
REDUCING
VALVEWITH
BY-PASS
0)
1
EXPANSION
TANK
(2)
PRESSURE GAUGE
WATER
SHUTOFF
RECOMMENDED INSTALLATION
(WRnCAL MOUNnNG)
SMELLY WATER
In each glasslined water heater there is installed at least one
anode rod (see parts section) for corrosion protection of the
tank. Certain water conditions will cause a reaction between this
rod and the water. The most common complaint associated with
the anode rod is one ofa _rotten egg smell". This odor is derived
from hydrogen sulfide gas dissolved in the water. The smell is
the result of four factors which must all be present for the odor
to develop:
a. a concentration of sulfate in the supply water.
b. little or no dissolved oxygen in the water.
c. a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
d. an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.
WATER HEATER
COLD WATER
INLET FITTING
HOT
COLD
O)
EXPANSION
FLOOR, C EIUNG
jols'l; ETC.
STRAPPING
o)
PRESSURE
REDUCING
INLET COLD
VALVEWITH
WATER
BY-PASS
SHUTOFF
Smellywater may be diminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
lines. Contact Sears Service for Furtherinformation concerning
an Anode Replacement Kit #9001453 and this Chlorination
Treatment.
If the smelly water persists after the anode replacement and chlo-
rination treatment, we can only suggest that continuous chlori-
nation and filtering conditioning equipment be considered to
eliminate the water problem.
Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
"AIR"
IN HOT WATER
FAUCETS
PRESSUREGAUGE
ALTERNATE RECOMMENDED
INSTALLATION
(HORIZONTAL MOUNTING)
STRANGE
SOUNDS
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmFul or dangerous conditions.
AWARNING
HYDROGEN GAS: Hydrogengas can be produced in a hot
water system thet hasnet been reedfor a longperledof _rne
(generally two weeks .or more). Hydrogen gas is extremely
flammable and expiosve. To prevent the possibility of injury
under these conditions, we recommend the hot weter faucet
be opened for several minutes at the kitchen sink before any
electricalappliances w hichare €onnected to the hot waters_-
tern are used (such as a dishwasher or washing machine). If
hydrogen gas is present, there will probably be an unusual
sound similar to air escapingthrough the pipe as the hot water
faucet is opened. There must be no smoking or open flame
near the faucet at the time it isopen.
Condensation
causes sizzling and popping
with the burner area
during heatin_
and coolin_
periods
and should
be considered
normal. See Condensation
section.