Quick Links

Remote Control Unit

Operating Instructions

AJ-
P
Model No.
Before operating this product, please read the instructions carefully and save this manual for future use.
P
Printed in Japan
F0604W0 @
VQT0M57

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AJ-RC905P

  • Page 1: Remote Control Unit

    Remote Control Unit Operating Instructions Model No. Before operating this product, please read the instructions carefully and save this manual for future use. Printed in Japan F0604W0 @ VQT0M57...
  • Page 2 AC plug. Please contact built-in cabinet or any other confined space in either a local or foreign Panasonic authorized service order to maintain adequate ventilation. Ensure center for assistance in selecting an alternate AC that curtains and any other materials do not plug.
  • Page 3: Table Of Contents

    Thank you for purchasing the AJ-RC905 remote control unit (which will be referred to as “the unit” in these instructions). Connecting the unit to a camera recorder and camera adapter (AJ-CA905G) using a 26-pin multi-cable makes it possible to operate the camera recorder as a system camera and broaden the range of the applications and uses of the camera recorder.
  • Page 4: Precautions For System Connections

    Precautions for system connections Bear mind following points when $ Before performing the system adjustments for all connecting the camera recorder and unit as a the devices connected, turn on the power of the system. camera recorder. $ If, while a menu is displayed, the unit’s $ Do not input signals to the GENLOCK IN connector START/STOP button or VTR START/STOP button of the camera recorder.
  • Page 5: Features

    Features O The power is supplied to the camera recorder and O The camera recorder’s menus can be set directly. the signals are input and output by a 26-pin multi- For details of the menus, refer to the operating cable (maximum length: 100 meters). instructions accompanying the camera recorder.
  • Page 6 Parts and their functions Front panel VTR ENABLE switch This is set to ON when using the unit to operate the VTR part of the camera recorder. STOP PLAY REC CHK START/STOP ENABLE CALL MONITOR CHROMA CABLE LENGTH TALLY 100m VTR WARNING The VTR part of the camera recorder is operated SET UP...
  • Page 7 Parts and their functions Front panel BAR button This is used to switch the images which are output to color bar signals. STOP PLAY REC CHK START/STOP When lighted: ENABLE CALL MONITOR CHROMA CABLE LENGTH The color bar signals of the camera recorder are 100m TALLY VTR WARNING...
  • Page 8 Parts and their functions Front panel AUTO IRIS button This is used to set the auto iris function to ON or OFF. STOP PLAY REC CHK START/STOP When lighted: ENABLE CALL MONITOR CHROMA CABLE LENGTH The auto iris function is ON. TALLY 100m VTR WARNING...
  • Page 9 Parts and their functions Front panel STOP PLAY REC CHK START/STOP ENABLE CALL MONITOR CHROMA CABLE LENGTH 100m TALLY VTR WARNING SET UP SHUTTER GAIN Y/VIDEO CHROMA WHITE AUTO KNEE (PUSH) POS2 POS3 PRST POS1 POS4 INTERCOM POS5 PAINTING POS6 GAIN DETAIL ENABLE...
  • Page 10: Rear Panel

    Parts and their functions Rear panel AUDIO OUT connector The audio signals of the camera recorder are (VJH1247) output from this connector. VIDEO IN VIDEO OUT GEN-LOCK Y/VIDEO MONITOR TALLY FUSE This is the fuse for the unit’s main power supply. Use a dedicated fuse (250 V, 2.5 A) which is COMMUNICATION INCOM IN...
  • Page 11: Setting The Internal Switches

    Setting the internal switches CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of fire or electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Remove the twelve screws, and take off the top cover.
  • Page 12: Connector Pin Signals

    Connector pin signals AUDIO OUT CAMERA INCOM IN POWER AUDIO IN (H) INCOM (H) AUDIO IN (C) MONITOR OUT INCOM (C) MONITOR OUT GND Maker part number: HA16RV-3PG Maker part number: HA16PRM-3SG Y GND (HIROSE ELECTRIC CO.LTD) (HIROSE ELECTRIC CO.LTD) Y OUT PUSH OUT GND...
  • Page 13: Specifications

    Specifications [GENERAL] [TALLY SIGNALS] Input: Contact/DC voltage supply (selected using internal switch) Power supply Output: Input: AC 100-240 V, 50/60 Hz, 80 W Open collector type, 10 mA max. inrush current, DC 12 V voltage Output: DC 18 V, max. 3 A indicates safety information.
  • Page 14 Specifications [INPUT CONNECTORS] GEN LOCK: BNC k2, 75 Ω, bridge RET: BNC k2, 75 Ω, bridge Communication: INCOM: XLR (3 pins), high impedance PGM: XLR (3 pins), high impedance AC IN socket: 3 pins [OUTPUT CONNECTORS] MONITOR: 1 line, BNC, 75 Ω Y, P 1 line, BNC, 75 Ω...
  • Page 15 Memo...
  • Page 16 PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7000 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835...