Outdoor Sensor Interface Module
APPLICATION
The Outdoor Sensor Interface Module allows a C7089U
outdoor sensor to be used to report outdoor temperature to
the EnviraCOM bus. The module is designed to enable
outdoor temperature sensing for VisionPRO
thermostats when used with W8835 EnviraZone zone control
panels. The Outdoor Sensor Interface Module is required
when using a C7089U temperature sensor with the W8835
Envirazone panel.
FEATURES:
• Can be wired into any of the 1,2,3 Enviracom terminals
on the W8835 panel.
• Mounts easily next to the W8835 panel.
• Easy push wire terminals that provide a secure lock
with no need to screw in wires.
INSTALLATION
1. The Outdoor Sensor Interface Module can be wall
2. The holes are sized for the #6 sheet metal screws.
3. Precise leveling of the product is not required.
4. Wire the 1,2, and 3 terminals on the Outdoor Sensor
5. Wire the 2 wires from the C7089U temperature sensor
®
IAQ TH9421
Fig. 1. Outdoor sensor interface module wiring diagram.
INSTALLATION INSTRUCTIONS
mounted in any orientation desired or dictated by the
surroundings.
Interface Module to the 1,2, and 3 terminals on the
W8835 panel.
into the OT terminals. One wire inserted into 1 OT termi-
nal, the other wire inserted into the other OT terminal.
OUTDOOR SENSOR INTERFACE
MODULE - 50022037
1
2
3
OT
1
2
3
W8835 PANEL
50022037-001
OT
C70809U OUTDOOR
TEMPERATURE SENSOR
M23812
69-2043EFS

Advertisement

loading

Summary of Contents for Honeywell 50022037-001

  • Page 1 W8835 EnviraZone zone control panels. The Outdoor Sensor Interface Module is required when using a C7089U temperature sensor with the W8835 Envirazone panel. C70809U OUTDOOR TEMPERATURE SENSOR W8835 PANEL M23812 Fig. 1. Outdoor sensor interface module wiring diagram. 50022037-001 69-2043EFS...
  • Page 2 Module d'interface pour capteurs de température extérieure DIRECTIVES D'INSTALLATION CARACTÉRISTIQUES : • Peut être raccordé aux bornes 1, 2 ou 3 EnviraCOM du tableau W8835. • S'installe facilement près du tableau W8835. • Bornes à cosse enfichables; nul besoin de resserrer une vis sur les fils.
  • Page 3 Módulo de interfaz de sensor para exteriores INSTRUCCIONES DE INSTALACIÓN CARACTERÍSTICAS • Puede conectarse a cualquiera de los terminales 1, 2 y 3 EnviraCOM del panel W8835. • Se monta fácilmente al lado del panel W8835. • Cables con terminales fáciles de insertar que brindan una traba segura sin que sea necesario asegurar con tornillos los cables.
  • Page 4 1985 Douglas Drive North 35, Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® Marca Registrada en los E.U.A © 2007 Honeywell International Inc. todos Los Derechos Reservados ® U.S. Registered Trademark © 2007 Honeywell International Inc. 69-2043EFS M.S. 01-07...