Maintenance Indicators - Sharp Conference Series XG-PH80W-N Operation Manual

Hide thumbs Also See for Conference Series XG-PH80W-N:
Table of Contents

Advertisement

Maintenance Indicators

The warning lights (POWER indicator, TEMP. (temperature warning)/STATUS indicator and
LAMP indicator) on the projector indicate problems inside the projector.
If a problem occurs, either the TEMP. (temperature warning)/STATUS indicator or the LAMP
indicator will illuminate red, and the projector will enter Standby mode. After the projector
has entered Standby mode, follow the procedures given below.
Top View
About the TEMP. (temperature warning)/STATUS indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting
location, the lamp will turn off, the cooling fan will run and then the projector will enter Standby
mode, and then the TEMP. (temperature warning)/STATUS indicator will blink. When you fi nd the
TEMP. (temperature warning)/STATUS indicator blinking, be sure to perform the measures
described on page 65.
About the LAMP indicator
When the remaining lamp life becomes 5% or less,
Lamp.(LAMP1/2)" will be displayed on the screen. When the percentage becomes 0%, it will
change to
automatically enter Standby mode. At this time, the lamp indicator will illuminate in red.
If you try to turn on the projector a fourth time without replacing the lamp, the
projector will not turn on.
Indicators on the Projector
POWER indicator Red on
LAMP indicator
TEMP.
(temperature
warning)/STATUS
indicator
64
LAMP (1, 2) indicators
TEMP. (temperature warning)/STATUS indicator
POWER indicator
(red), the lamp will automatically turn off and then the projector will
Normal (Standby)
Green on
Normal (Power on)
Orange blinks
Normal (Cooling)
Green blinks
Normal (Warming up)
Green on
Normal ("Eco + Quiet" is "Off".)
Orange on
Normal ("Eco + Quiet" is "On".)
Green blinks
The lamp is warming up. ("Eco + Quiet" is "Off".)
Orange blinks
The lamp is warming up. ("Eco + Quiet" is "On".)
Red on/Red blinks The lamp is shut down abnormally or requires to be
changed. (See page 65.)
Off
Normal
Red/Orange
Abnormal. (See page 65.)
blinks
(yellow) and "Change The