Download Print this page
Honeywell SmartVFD Installation Instructions
Honeywell SmartVFD Installation Instructions

Honeywell SmartVFD Installation Instructions

Three contactor bypass assemblies
Hide thumbs Also See for SmartVFD:

Advertisement

Quick Links

Honeywell SmartVFD
Three Contactor Bypass Assemblies
APPLICATION
The SmartVFD Three Contactor Bypass Assemblies channel
electrical power either through or around the Variable
Frequency Drive (VFD).
INSTALLATION
1. Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instruction, Honeywell
SmartVFD manual to make sure the product is suitable
for your application.
3. Verify bypass model is correct; no damage has been
incurred; no screws, connections, and terminations are
loose.

INSTALLATION INSTRUCTIONS

4. Installer must be a trained, experienced service
technician, with VFD operation experience.
5. After installation is complete, check out product
operation as provided in these instructions.
WARNING
1. Installation requires work with voltages that may
cause serious injury or death.
2. This instruction manual is intended as a guide only.
End user is responsible for proper application of
this assembly, insuring proper conformance,
directives, intended use and maintaining all safety
practices as described in Honeywell SmartVFD
manual, local codes, and local safety authorities.
3. Disconnect power supply before installation, and
before any servicing.
LOCATION AND MOUNTING
Locate the device in a clean, dry, well-ventilated area with an
ambient temperature below 104°F (40C). Refer to SmartVFD
user manual "Mounting and Cooling" for free air space
requirements above and to the sides of SmartVFD. Insure
proper branch/short circuit protection is provided.
WIRING
IMPORTANT
All wiring must agree with applicable codes,
ordinances and regulations. Variable Frequency
Drives can store energy. Refer to VFD manual for
safe work practices and appropriate wait times
before servicing after equipment power has been de-
energized. All safety, warning and caution
information located in Honeywell SmartVFD manual
must be read, understood and followed.
1. Ensure that bypass panel voltage corresponds with that
of the power supply.
2. To access the bypass panel wiring compartment:
(1)
Ensure the main disconnect handle is in the
OFF position.
(2)
Open the cover.
(3)
Test for power.
Put Bar Code Here
62-2028-01

Advertisement

loading

Summary of Contents for Honeywell SmartVFD

  • Page 1: Installation Instructions

    Locate the device in a clean, dry, well-ventilated area with an ambient temperature below 104°F (40C). Refer to SmartVFD user manual “Mounting and Cooling” for free air space requirements above and to the sides of SmartVFD. Insure proper branch/short circuit protection is provided. WIRING...
  • Page 2 HONEYWELL SMARTVFD THREE CONTACTOR BYPASS ASSEMBLIES 3. Refer to SmartVFD user manual “Specification for If motor is rotating backwards in VFD mode, Wiring Terminals” for proper power and control wire shut down power, lock out power source, wait sizing information.