INSTALLATION
STEP
6
Install the Door Control
Locate door control within sight of door, at a minimum height of
5 feet (1.5 m) where small children cannot reach, away from
moving parts of door and door hardware.
1. Strip 1/4" (6 mm) of insulation from one end of bell wire and
connect to the two terminal screws on back of door control by
color: white to 2 and white/red to 1.
2. Fastenthe Door Control Button securely with 6ABx1-1/2"
screws. If installing into drywall, drill 5/32" holes and use the
anchors provided.
3. Run bell wire up wall and across ceiling to motor unit. Use
insulated staples to secure wire in several places. Do not pierce
wire with a staple, creating a short or open circuit.
4. Connect the bell wire to the terminal screws on the motor unit
panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment warning
label to wall near door control, and manual release/safety
reversetest label in a prominent location on inside of garage
door.
NOTE: DO NOT connect power and operate opener at this time.
The trolley will travel to the furl open position but will not return to
the close position until the sensor beam is connected and properly
aligned.
To prevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLTlow voltage wires.
To prevent possible SERIOUSINJURYor DEATHfrom a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.
• NEVERpermit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keepgarage door in sight until completely closed.
NEVERpermit anyone to cross path of closing garage door.
HARDWARESHOWN ACTUALSIZE
_1111111111111111111111111111111_>
_
_
Screw 6ABx1-1/2"
Insulated
Lighted Door Control Button
Drywall Anchors
Staples
Terremina, ,
(BACK VIEW)
DOOR CONTROL
BUTTON
Quick-Connect
To release or insert wire,
push in tab with
screwdriver
tip
Strip wire 7/16"
(11 mm)
17/16"
(11 mm)l
Door Control
Connections
White
Grey
Antenna