Download Print this page

Craftsman 580.328301 Owner's Manual page 8

120/240 volt electric start 10,000 watt ac generator

Advertisement

HOW TO USE YOUR GENERATOR
If you have any problems operating your generator,
please call the generator helpline at 1-800-222-3136.
Grounding
The Generator
The National Electrical Code requires that the
frame and external electrically conductive parts of
this generator be properly connected to an
approved earth ground. Local electrical codes may
also require proper grounding of the unit. For that
purpose, a grounding lug is provided on the base of
the cradle.
TO START THE ENGINE
CAUTION!
Never start or stop engine with electrical
devices plugged into the receptacles AND devices
turned ON.
Unplug all electrical loads from generator
receptacles before starting the engine.
Make sure the unit is in a level position.
Open the fuel shut-off valve.
\
FUEL
TANK
Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding lug and
to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against
electrical shock. However, local codes may vary
widely. Consult with a local electrician
for
grounding
requirements
in your area.
Proper grounding
of generator
will help prevent
electrical
shock
in the event of a ground fault
condition in the generator or in connected electrical
devices. Proper grounding also helps dissipate static
electricity, which often builds up in ungrounded
devices.
Connecting
Electrical
Loads
Let engine stabilize and warm up for a few minutes
after starting.
Plug in and turn on the desired 120 Volt or
240 Volt, single phase, 60 Hz electrical loads.
Do Not connect 240 Volt loads to 120 Volt
receptacles.
Do Not connect 3-phase loads to the generator.
Do Not connect 50 Hz loads to the generator.
Add up the rated watts (or amps) of all loads to be
connected at one time. This total should not be
greater than (a) the rated wattage/amperage
capacity of the generator or (b) circuit breaker
rating of the receptacle supplying the power. See
"Don't Overload the Generator" on page 12.
J
Fuel Valve is shown
in the On position
Pull the choke knob to close. If the engine is warm,
or the ambient temperature is high, pull the choke
knob half-way, or keep it fully open.
Close
/
/
\
Turn the key switch to the "Start"
position.
IMPORTANT:
Do Not operate the electric starter
continuously for more than 5 seconds, even if the
engine does not start. Extended cranking can damage
the starter motor.
NOTE: If engine fails to start, set the key to the "Run"
position and wait for about 10 seconds before retrying.
IMPORTANT:
Never turn the key switch to the "Start"
position while the engine is running. You could
damage the starter motor.
When the engine starts, gradually open choke by
pushing the choke knob and keep it fully opened
while running.

Advertisement

loading