Craftsman 580.326300 Owner's Manual
Craftsman 580.326300 Owner's Manual

Craftsman 580.326300 Owner's Manual

6300 watt electric start ac generator
Hide thumbs Also See for 580.326300:

Advertisement

Available languages

Available languages

Owner's
Manual
®
Start
AC
Model No.
580.326300
GENERATOR
CU8TOMER
HELPLJNE
HOURS:
Non. - Fri. 8 a.m. to 5 p.m. (CT)
CAUTION
Before using this product, read this
manual and follow all Safety Rules and
Operating Instructions.
Sears,
Roebuck
and Co.,
Hoffman
Estates,
_L 60179
U.S.A.
Visit our Craftsman
website:
www.craftsmamcom
Part No. 191759 Draft 4 (I2/15/2004)
PRECAUCION
Antes de utilizar el producto, lea este
manual y siga todas las Reglas de
Seguridad e Instrucciones de Uso.
o Safety
o Assembly
o Operation
o Maintenance
o Parts
o Espa_oN
0
3

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 580.326300

  • Page 1 Safety Rules and manual y siga todas las Reglas de o Espa_oN Operating Instructions. Seguridad e Instrucciones de Uso. Sears, Roebuck and Co., Hoffman Estates, _L 60179 U.S.A. Visit our Craftsman website: www.craftsmamcom Part No. 191759 Draft 4 (I2/15/2004)
  • Page 2 WARRANTY ........TROUBLESHOOTING ......SAFETY RULES ....... SCHEMATIC DIAGRAM ......FEATURES AND CONTROLS ...... WIRING DIAGRAM ......ASSEMBLY ........REPLACEMENT PARTS ....... 20°28 OPERATION ......... 8-11 NOTES ........SPECIFICATIONS ....... EMISSION CONTROL WARRANTY ....30o31 MAINTENANCE ......13o15 ESPA!_OL ........32o51 STORAGE ........
  • Page 3 This is the safety alert symbol. It is used to alert you to potentiam personal inju_' hazards. Obey all safety messages that foltow this symbol to avoid possible injury or death. WARNING ii-!-j_ij Read this manuat carefully and become familiar with your pressure washer. Know its applications, its limitations,...
  • Page 4 WARNING WARNING WHEN ADDING OR DRAINmNG FUEL WHEN ADJUSTING OR MAKING REPAIRS TO YOUR Turn generator OFF and let it cool at least 2 minutes GENERATOR before removing fuel cap. Loosen cap slowly to relieve + Disconnect the spark plug wire from the spark plug and pressure in tank.
  • Page 5 KNOW YOUR GENERATOR Read the owner's manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Fuel Valve Rocker Switch (on engine shroud) (not shown)_./) Fuel Tank...
  • Page 6 You will need a socket wrench with 1/2" or 13mm sockets and a needle-nose plier to install this kit. Your Craftsman generator requires some assembly and is ready for use only after it has been properly Refer to illustration shown below and install the wheel serviced with the recommended oil and fuel.
  • Page 7 Slowly fill engine with oil through oil fill opening Check Battery t Attach Negative Battery Wire until oil level is to the point of overflowing. Install yellow oil fill cap and finger tighten securely. The sealed battery on the generator is fully charged and pre-installed except for the negative (black) Check engine oil level before starting each time...
  • Page 8 HOW TO USE YOUR GENERATOR Generator Location if you have any problems operating your generator, Generator Clearance please ca++ the generator helpline at 1=800-222-3136+ WARNtNG System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.
  • Page 9 TO START THE ENGINE WARNING CAUTION See "Don't Overload Generator", When starting engine, pull cord slowly until resistance Start generator and let engine stabilize before connecting felt and then pul! rapidly to avoid kickback, electrical loads, NEVER start or stop engine with electrical devices Connect...
  • Page 10 Move rocker switch to "Off" position. 120/240 Volt AC, 30 Amp Receptacle Move fuel valve to "Off" position. This is a full capacity receptacle; it can supply the generator's full rated output from this sole outlet. The CONNECTING ELECTRICAL LOADS outlet is protected by two 30 Amp push-to-reset circuit breakers.
  • Page 11 DON'T OVERLOAD GENERATOR Plug in and turn on the next load. Again, permit the generator to stabilize. Capacity Repeat steps 4 and 5 for each additional load. You must make sure your generator can supply NEVER add more loads than the generator capacity. enough rated (running) and surge (starting) watts for Take special care to consider surge loads in generator the items you will power at the same time.
  • Page 12 ENGINE TECHNICAL aNFORMATtON PRODUCT SPECIFICATIONS This is a single cylinder, overhead valve(OHV), air Generator Specifications cooled engine, it is a low emissions engine. Rated Maximum Power ..6300 Watts (6.3 kW) in the State of California, Model Series 210000 Surge Power ....9100 Watts (9.1 kW) engines are certified by the California Air Resources Rated AC Voltage ....
  • Page 13 OWNER'S RESPONSIBILITIES Follow the hourly or calendar intervals, whichever occurs first. More frequent service is rec uired when operating in adverse conditions noted below. MABNTENANCE SCHEDULE FtLL tN DATES AS YOU SERVICE DATES COMPLETE REGULAR SERVICE SERVICE DATES Every 100 Before Every 25 Hours Every 50 Hours...
  • Page 14 ENGINE MAINTENANCE Replace spark plug if electrodes are pitted, burned or porcelain is cracked. Use a recommended WARNING replacement plug. NOTE: You can purchase a new spark plug by calling 1-800-366-PART. Service Air Cleaner Your engine will not run properly and may be damaged if you run it using a dirty air cleaner.
  • Page 15 inspect screen and replace if torn, perforated or WARNING otherwise damaged. DO NOT use a defective screen. If screen is not damaged, clean it with commercial solvent. Reattach screen and muffler guard. Air Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine DO NOT touch hot surfaces.
  • Page 16 Change OH While engine is still warm, drain oil from crankcase. Thegenerator shouldbestarted atleastonceevery Refill with recommended grade. sevendaysandallowed torunat least30minutes. I f thiscannot b edoneandyoumuststoretheunitfor OHCylinder Sore morethan30days,usethefollowing information a s a guideto prepare itforstorage. • Remove spark plug and pour about 1 ounce (30ml) of clean engine oil into the cylinder.
  • Page 17 Prob{em Correction C_use One of the circuit breakers is Reset circuit breaker. open. Poor connection or defective Check and repair. Engine Bsrunning, but no AC cord set. output is available. Connected device is bad. Connect another device that is in good condition. Fault in generator.
  • Page 18 CRAFTSMAN 6300 Watt AC Generator 580.326300 PI]WER PI-2 P1-4 120V IBO/240V WHITE BATTERY CHARGE FUSE...
  • Page 19 CRAFTSMAN 6300 Watt AC Generator 580.326300 £B BLACK (33) FLOAT CHARGER BLUE SUPPLIED BATTERY BATTERY CHARGE RECTIFIER...
  • Page 20: Main Unit - Exploded View

    CRAFTSMAN 6300 Watt AC Generator 580.326300 Main Unit m E×p_oded View DET£-IL JACK 5SSEVBLY COAXIAL DETA_ BATTERY TRAY DETAIL E[ECTRC START S/NITCH S[ARTER TO RBC b TERMINAL BATTERY...
  • Page 21 CRAFTSMAN 6300 Watt AC Generator 580.326300 Main Unit m Parts List Item Part # Part # Description Item Description M190305GS CRADLE WASHER, M6 Shakeproof 194150GS 188333GS KIT, Mount, Vibration, 45 ° DECAL, instruction, Fuel Level 190220GS 194799GS HOUSING, Engine Adapter...
  • Page 22 CRAFTSMAN 6300 Watt AC Generator 580.326300 Contro{ Pane{ m Exp{oded View and Parts List Item Part # Description 195112GS KIT, Control Panel Lid 191450GS CONTROL PANEL, Compact 68759GS OUTLET, 120V, 20Amp, Duplex NUT, Palnut, 5/32 84198GS CAP, Circuit Breaker 75207AGS...
  • Page 23 CRAFTSMAN 6300 Watt AC Generator 580.326300 Wheel Kit m Exploded View and Parts List @ ..Item Part # Description VVASHER, 5/8 B4966GS WHEEL 191267GGS AXLE, 5/8" x 23.62" 191265GS E-RING, 5/8 HHCS, M8- 1.25 x 20 B187101GS LEG, Support...
  • Page 24 CRAFTSMAN 6300 Watt A¢ Generator 580.326300 Alternator m E×p[oded View and Parts List i _- \ Item Part # Description 186059GS ADAPTER, Mounting, Alternator 191876GS ROTOR 192196AGS STATOR 186060GS RBC, with OzRing (p/n 189197GS) 86308HGS SCREW 66386GS ASSY, Holder, Rectifier/Brush...
  • Page 25 ENGINE, 11 HP, Briggs and Stratton, 210415 - Exploded View 718A 22 _:_ 27 o...
  • Page 26 ENGINE, 11 HP, Briggs and Stratton, 210415 - Exploded View 1026_ 798_ 4s _ 1100 8 564A 564 _ 1171 GASKET SET CARBURETOR 137_ 633 @ 1 _L_ 163_ 633 @ 121 CARBURETOR OVERHAUL 117 ® 163_ 633@...
  • Page 27 ENGINE, _1 HP, Briggs and Stratton, 210415 - Exploded View 579 _ 310_% 1070 332_ ENGINE GASKET 8680 689 % 5iA_ i21i i095 VALVE GASKET i2i0 65 _®...
  • Page 28 ENGINE, HP, Briggs and Stratton, 210415 - Parts List item PaR # Description item Part # Description 697702 Cylinder Assembly 697240 Shield-Cylinder 697719 Kit-Bushing/Seal (Magneto Side) 691660 Screw (Cylinder Shield) 391086 Motor-Starter Seal-Oil (Magneto Side) 695479 697233 Head-Cylinder 690323 Bolt (Starter Motor) 697690 Brush Set Gasket-Cylinder...
  • Page 30 Sears, Roebuck and Co., U.S.A. (Sears), the California Air Resources Board (CARB) the United States Environmenta_ Protection Agency (U.S.EPA) Emission Contro_ System Warranty Statement (Owner's Defect Warranty Rights and Obligations) EMiSSiON CONTROL WARRANTY COVERAGE Fuel Metering System APPLICABLE TO CERTIFIED ENGINES PURCHASED Cold start enrichment...
  • Page 31 Emissions Durability Period and Air index Emissions Compliance Period On Engine Information On Your Engine Emissions Labe_ Emissions Compliance Labe_ Engines that are certified to meet the California After July 1,2000 certain Sears engines will be certified Resources Board (CARB) Tier 2 Emission Standards must...
  • Page 32 ......38o41 PARTES/SERVICIO ....ULTJMA PAGINA ESPECIFICACIONES DEL PRODUCTO ..... GARANTIA LIMiTADA DE GENERADOR PORTATtLE CRAFTSMAN SEARS garantiza al comprador original que el altemador y el motor para su generador portati! estaran Iibres de defectos los materiales o la mano...
  • Page 33 Este es el simbolo de alerta de seguridad. Es usado para indicarle situaciones con peligros potenciales lesion para e[ persona[. Siga [as instrucciones de todos los mensajes de seguridad que aparecen despues este simbo[o para evitar posibJes [esiones o muerte. Lea este man°a, de maoera co,dodosa...
  • Page 34 ADVERTENCIA CUANDO ANADA COMBUSTIBLE O VACiE CUANDO AJUSTE O HAGA REiPARACIONES A SU DEP6SITO GENERADOR Apague et generador (posici6n OFF) y d6jelo enfriar al menos por Siempre desconecte et atambre de ta bujia y col6quelo donde 2 minutos antes de remover ta tapa de ta combustible. Afloje ta no pueda entrar en contacto con la bujia.
  • Page 35 CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROP{ETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR, Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 36 Consulte la ilustraci6n mostrada e instale el juego ruedas como se describe a continuaci6n: Su generador requiere de ciertos procedimientos de montaje y Coloque el fondo de la camilla del generador en una solo estara listo para ser utilizado despues de haberle superficie plana.
  • Page 37 Necesitara una dos Ilaves inglesas de 8mm para instalar Verifique el nivel de aceite de motor antes de comenzar cable negativo de la bateria. cada vez despues. Si el nive! de aceite esta debajo punto de derramar, !lena al nivel apropiado. Para insta[ar: NOTA: Revise...
  • Page 38 COMO USAR SU GENERADOR Ubicaci6n del Generador Si tiene problemas operando su generador, por favor Ilame Espacio Libre A[rededor de[ Generador a la linea de ayuda para generadores a! 1o800o222o3136. Tierra de_ Sistema El generador dispone de una conexion a tierra del sistema que conecta los componentes dei bastidor...
  • Page 39 PARA ENCENDER EL MOTOR PRECAUCtON Yea "No sobrecargue generador". Cuando arranque et motor, tire tentamente del cable hasta sentir una resistencia y, a continuaci6n, tire rapidamente de 61 Encienda su generador y deje que el motor se estabilice antes para evitar su retroceso. de conectar tas cargas el6ctricas.
  • Page 40 Mueva interrupter del motor a posici6n 'Off" (Apagado). Tomacorriente de 1201240 Voltios 30 Amperios Gire valvula a posicion "Off" (Apagado). Este es un tomacorriente de capacidad total, Io que significa CONEXION DE CARGAS que usted puede tomar e! vatiaje nominal total de este solo ELECTRtCAS tomacorriente.
  • Page 41 NO SOBRECARGUE GENERADOR Conecte y encienda la proxima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos 4 y 5 para cada carga adicional Usted debe asegurarse que su generador puede proveer usted tenga. suficiente vataje calificado (cuando este funcionando) y de...
  • Page 42 INFORMACION Tg:CNICA SOBRE EL ESPECIFICACtONES MOTOR PRODUCTO El motor es de uno cilindros, de valvulas en cabeza (OHV), Especificaciones del Generador refrigerado por aire y de baja emisi6n. Potencia M&xima ....6,300 vatios (6.3 kW) En e! Estado de California, los motores de la serie 210000 Potencia...
  • Page 43 RESPONSIBILADES DEL CLIENTE Siga los intervalos horarios o de calendario,_ue ocurra primero. Se requiere de servicio con mayor frecuencia cuando opere la unidad en las condiciones adversas descritas a continuaci6n. CALENDARIO DE MANTENIMIENTO INTERVALO DE OPERACION POR HORA ANOTE LAS FECHAS CONFORME CUMPLA CON EL SERVICIO NORMAL FECHAS...
  • Page 44 Mantenimiento de [a Bater[a LimpelReemplace la Bujia De otra manera que chorrea un poco cargar, descrito Cambie la bujia cada 100 horas de operacion o una vez al otra parte, la conservaci6n ningOn otro se requiere para la aSo, Io que suceda primero.
  • Page 45 Arme la cubierta m&s limpia aerea en la base y apriete Limpie e inspeccione el apagachispas de la siguiente los tomillos. manera: Para retirar la protecci6n del silenciador, retire los NOTA: Si necesita oredenar un filtro de pape! nuevo, cuatro tornillos que conectan la proteccion...
  • Page 46 GENERALIDADES Cambio de Aceite Con el motor todavia caliente, drene e! aceite de la caja del El generador deber& ser encendido al menos una vez cada cig_eSaJ. Vuelva a !lenarlo con el grado de aceite siete dias y debera dejarlo funcionar al menos durante...
  • Page 47 Problemo Accion Causa El interruptor automatico de circuito Reposicione el interruptor, esta abierto, Conexi6n real o defectuosa Revise y repare, juego de cables. EJ motor est_ funcionando pero existe salida de A¢ disponsibJe. El dispositivo conectado esta Conecte otro dispositivo que este da_ado.
  • Page 50 Sears, Roebuck and Co., U.S.A. (Sears), California Resources Board (Consejo de Recursos sobre e[ Aire California, CARB, pot sus sig[as en ingles) y United States Environmental Protection Agency (Agencia de Protecci6n Ambienta[ de EE.UU., EPA, por sus sig[as en ingles). Dec[araci6n de garantia de[ sistema...
  • Page 51 Jnformaci6n Sobre el Periodo Periodo de Cump_imiento de _a Normativa Durabilidad de las Emisiones y e_ indice de Emisiones en ia Etiqueta de Aire en _a Etiqueta de Emisiones CumpHmiento de Emisiones del Motor Motor Desde el 1 de julio de 2000, algunos motores Sears...
  • Page 52 Your Home For repair-in your home-of aH major brand appliances lawn and garden equipment,or heatingand cooling systems, no matter who made it, no matter who sold it! For,the replacement parts, accessories owner s manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.

Table of Contents