Appendix C
Connecting to DC Power
An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure
Warning
that no exposed portion of the DC-input power source wire extends from the terminal block plug.
Statement 122
Figure C-9
1
Return (positive) Feed A
2
Supply (negative) Feed A
Use a ratcheting torque screwdriver to torque the terminal block captive screw (above the installed wire
Step 6
lead) to 4.5 lbf-in. (72 ozf-in.). (See
Do not overtorque the terminal-block captive screws. The recommended maximum torque is 4.5 lbf-in.