System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
error code ([dec]) while configuration was being saved
Explanation
configuration copy is considered as failed.
Recommended Action
Support web site http://www.cisco.com/tac.
Error Message
configuration in the timeout period
Explanation
configuration into the startup-config. The overall configuration copy is considered as failed.
Recommended Action
Support web site http://www.cisco.com/tac.
Error Message
store its configuration in the timeout period
Explanation
configuration into the startup-config. The overall configuration copy is considered as failed.
Recommended Action
Support web site http://www.cisco.com/tac.
Error Message
with signal ([dec]) while configuration was being saved
Explanation
configuration copy is considered as failed.
Recommended Action
Support web site http://www.cisco.com/tac.
Error Message
to store its configuration (error-id [hex]).
Explanation
overall configuration copy is considered as failed.
Recommended Action
and the service [chars] is behaving correctly. Then try again.
OL-15994-03
SYSMGR-3-CFGWRITE_SRVTERMINATED: Service [chars] terminated with
A required service has terminated while configuration was being saved. The overall
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
SYSMGR-3-CFGWRITE_SRVTIMEOUT: Service [chars] failed to store its
A required service has failed to send a response after receiving a request to store its
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
SYSMGR-3-CFGWRITE_SRVTIMEOUT: Service [chars] in vdc [dec] failed to
A required service has failed to send a response after receiving a request to store its
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
SYSMGR-3-CFGWRITE_VDCSRVCRASHED: Service [chars] in vdc [dec] crashed
A required service has crashed while configuration was being saved. The overall
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
SYSMGR-3-CFGWRITE_VDCSRVFAILED: Service [chars] in vdc [dec] failed
A required service has failed to store its own configuration into the startup-config. The
Use the 'show process' command to verify that the system is running properly
Cisco NX-OS System Messages Reference
SYSMGR Messages
2-699