In the following procedure, the existing VSAN has a switch C-186 with a domain ID of 209. In Fabric
Manager, the VSAN is statically configured and a persistent FC ID is enabled. This procedure does not
alter the running domain ID.
To configure a static domain ID for an existing VSAN and enable a persistent FC ID for the same VSAN
using Fabric Manager, follow these steps:
Step 1
In the Logical Domains pane, expand the VSAN to be modified and then choose Domain Manager. See
Figure
Click the Configuration tab.
Step 2
Step 3
Enter the domain ID that is in the Running DomainID (in
Domain Id field.
Change the Config Domain IdType field to static.
Step 4
Click the green Apply Changes... icon
Step 5
Figure C-1
Click the Persistent Setup tab.
Step 6
Step 7
Check the Enable check box.
Step 8
Click Apply Changes.
At this point, the domain ID has been statically set and FC IDs will remain persistent across reboots for
VSAN 3000 on the switch C-186. The persistent FC ID database can be viewed in the Persistent Fcids