Configuring Online Diagnostics

S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Configuring Online Diagnostics
You can configure the bootup diagnostics to run the complete set of tests, or you can bypass all bootup
diagnostic tests for a faster module boot up time.
We recommend that you set the bootup online diagnostics level to complete. We do not recommend
Note
bypassing the bootup online diagnostics.
To configure the bootup online diagnostics level, perform these steps:
Command
Step 1
switch# configure terminal
Step 2
switch(config)# diagnostic bootup level
[complete | bypass]
Step 3
switch# show diagnostic bootup level
The following example shows how to configure the bootup diagnostics level to trigger the complete
diagnostics:
switch# configure terminal
switch(config)# diagnostic bootup level complete

Verifying Online Diagnostics Configuration

To display online diagnostics configuration information, perform one of the following tasks:
Command
show diagnostic bootup level
show diagnostic result module slot

Default Settings

Table 24-6
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
24-4
lists the default settings for online diagnostics parameters.
Chapter 24
Purpose
Enters configuration mode.
Configures the bootup diagnostic level to trigger
diagnostics when the device boots, as follows:
complete—Performs all bootup diagnostics. This
is the default value.
bypass—Does not perform any bootup
diagnostics.
(Optional) Displays the bootup diagnostic level
(bypass or complete) that is currently in place on the
switch.
Purpose
Displays the bootup diagnostics level.
Displays the results of the diagnostics tests.