Wsw10 Protocol Definition - Brother IntelliFax-3550 Service Manual

Facsimile equipment
Table of Contents

Advertisement

Selector
No.
Switching of DPS, following the
1
CML ON/OFF
Time length from transmission
2
of the last dial digit to CML ON
Time length from CML ON to
3
CNG transmission
Time length from CML ON to
4
CED transmission (except for
facsimile-to-telephone switching)
5
No. of training retries
6
7
Encoding system
(Compression)
8
Selector 1:
Switching of DPS, following the CML ON/OFF
Setting this selector to "1" automatically switches DPS following the CML ON/OFF operation.
This function is provided to conform to the Swedish standard.
Selector 2:
Time length from transmission of the last dial digit to CML ON
This selector sets the time length from when the equipment transmits the last dial digit until
the CML relay comes on.
Selector 3:
Time length from CML ON to CNG transmission
This selector sets the time length until the equipment transmits a CNG after it turns ON the
CML relay.
Selector 4:
Time length from CML ON to CED transmission
This selector sets the time length until the equipment transmits a CED after it turns ON the
CML relay. This setting does not apply to switching between facsimile and telephone.
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
Selectors 7 and 8:
Encoding system (Compression)
This selector determines whether or not use of the MR coding system will be allowed.
(Swiss version only)
WSW10
(Protocol definition 2)
Function
MR
MMR
V – 23
Setting and Specifications
0: No
1: Yes
0: 100 ms
1: 50 ms
0: 2 sec.
1: 4 sec.
0: 0.5 sec.
1: 2 sec.
No. 5
6
0
0
:
1 time
0
1
:
2 times
1
0
:
3 times
1
1
:
4 times
0: Allowed
1: Not allowed
0: Allowed
1: Not allowed