Honeywell 5828V - Ademco Wireless Talking Keypad Installation And Setup Manual page 3

Wireless bidirectional fixed-word keypads

Advertisement

If you select "1" (normally used on LYNX controls)
Function Key
Function
A
"Off"
B
Arms "AWAY"
C
Arms "STAY"
D
(For future use)
MEMO/MESSAGE CENTER
The MESSAGE CENTER table that follows explains what
can be done using the message center of the 5828V, and the
keys to press to enable each function.
NOTE: Allow any status annunciation to complete before
starting to record a message.
MESSAGE CENTER (LYNX)
TO:
Record a message:
Stop recording before end of 20 seconds:
Playback a message:
Adjust message playback volume:
Mute keypad status announcements:
Restore keypad status announcements:
MESSAGE CENTER (VISTA)
TO:
Record a message:
Stop recording before end of 20 seconds:
Playback a message:
Adjust message playback volume:
Mute keypad status announcements:
Restore keypad status announcements:
New message indication: When the keypad is activated in
battery-powered mode and a new message is waiting, the red
message LED will blink until the keypad turns off or the
message is played back.
When powered by AC, if a new message is waiting, the red
message LED will blink continuously until the stored
message has been played back.
When programming zone descriptors in the panel, you must select from words supported by both the 5828V
NOTE:
(shown in Table 1 below) and words supported by the control panel. If you use any other words, the 5828V will not
annunciate them. Refer to the control panel's Installation and Setup Guide for specific instructions on programming
zone descriptors.
ALARM
DOOR
ATTIC
EIGHT
BABY
EMERGENCY
BACK
EXIT
BASEMENT
FIRE
BATHROOM
FIRST
BEDROOM
FIVE
CHECK
FLOOR
DEN
FOUR
DETECTOR
FRONT
DINING
GARAGE
* These Descriptors are available with VISTA series control panels ONLY.
** This Descriptor is available with Lynx series control panels ONLY.
1. If installing a Lynx series system, please note that compound zone descriptors supported by the Lynx such as "living
room" are not supported on the 5828V, and should be programmed as two single words, "living" and "room." Also
note that the Lynx Voice Prompt Programming mode uses these compound words when applicable. These words
should be reprogrammed as two single words in order to be announced by the 5828V.
2. When using a VISTA-40 or VISTA-50P control panel, you must program zone descriptors in order for the panel to
announce the zone status correctly.
NOTE: If using a LYNX control, and the word "MESSAGE"
is announced at the 5828V keypad, it means that there is a
message waiting at the control panel, which can only be
retrieved using the LYNX keypad.
To delete a message: Recording a new message will
overwrite the old one.
Muting system status announcements has NO affect on
the message recording or playback capability.
If volume is adjusted (3↑ or 6↓) when a message is played
back, and the user still wants system status announcements
to be muted, the user must again mute system status
announcements (# + 2 + 1 for LYNX or # + 0 + 2 + 1 for
VISTA).
POWER CONNECTIONS
In a typical configuration, the 5828 and 5828V keypads are
PRESS:
powered by 3-AA batteries.
# + 1
The 5828 and 5828V keypads can also be powered from an
1
optional Power Pack/Desktop Mounting Kit. See detailed
# + 3
specifications for the Kit on the next page.
# + 2 + 3↑ or 6↓
# + 2 + 1
It is recommended that three AA batteries be installed as a
# + 2 + 3↑ or 6↓
backup power source when using the Power Pack/Desktop
Mounting Kit.
PRESS:
# + 0 + 1
SUPERVISION
1
A 5828/5828V keypad low battery condition will be
# + 0 + 3
displayed as "BAT" on Zone "00" until the battery drops
# + 0 + 2 + 3↑ or 6↓
below a minimum level and the display goes blank.
# + 0 + 2 + 1
The 5828/5828V does not display three-digit conditions, such
# + 0 + 2 + 3↑ or 6↓
as a keypad or receiver supervision failure. It will only
display the last two digits of the supervision zone number.
Therefore, it is recommended for VISTA-10P/15P/20P and
variants that you set program field *199 (ECP Fail
Display) as a "1" (two-digit display). This will cause the
keypad to display Zone 91 as a supervision failure of any
device on the keypad (ECP) bus.
TABLE 1. ZONE DESCRIPTORS
GUN
MOTION
INSIDE
NINE
INSTANT
OFFICE
KITCHEN
ONE
LAUNDRY
OPEN*
LIBRARY
PANIC*
LIVING
PATIO
MAIN
POOL
MASTER
MOTION
MEDICAL
ROOM
MESSAGE**
SECOND
- 3 -
SEVEN
THREE
SHED
TWO
SHOP
UPSTAIRS
SIDE
UTILITY
SIX
WINDOW
SLIDING
YARD
SMOKE
ZERO
STORAGE
ZONE
SEVEN
SYSTEM
THIRD

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ademco 5828