GENERAL INFORMATION
The ADEMCO 5828 and 5828V are wireless, bidirectional,
fixed-word, keypads that may be used in conjunction with
LYNX and VISTA series residential control panels. VISTA
systems require use of either a 5883 Transceiver (micro P/N
WAK5119-X, where X = 3 or higher), 6150RF Keypad/
Transceiver (PC board P/N SA6150RFAS-T3 or higher), or
6160RF Keypad/Transceiver. The 5828/5828V keypads are
not compatible with commercial control panels that have
three-digit zone numbers (e.g., VISTA128BP).
Both keypads provide:
Four programmable special function keys
Wall-mount plate for easy removal of the keypad and
battery replacement
Optional Desktop mount /AC adapter kit, ADEMCO
P/N 5828DM)
Battery-powered with 3-AA batteries
The 5828V keypad additionally provides:
Memo/Message center
Voice Response – system status, zone information, and
alarms with zone information
Stored Message LED indication
Built-in microphone and speaker
NOTES:
The 5828/5828V cannot be used as the primary system
keypad, and may not be used to program or test any
security system. All systems require a hardwired
keypad (or Compass Downloader) to do so. Once
programmed, the 5828/5828V can be used to initiate all
common functions of a fixed English keypad.
A
1
ARMED
B
4
READY
7
C
D
5828 Keypad with Front Cover Removed
A
ARMED
1
B
RECORD
READY
4
7
C
STATUS
D
5828V Keypad with Front Cover Removed
Wireless Bidirectional Fixed-Word Keypads
INSTALLATION AND SETUP GUIDE
2
3
OFF
AWAY
STAY
5
6
MAX
TEST
BYPASS
8
9
INSTANT
CODE
CHIME
0
#
READY
MIC
MESSAGE
2
3
OFF
AWAY
STAY
VOLUME
PLAY
5
6
MAX
TEST
BYPASS
8
9
INSTANT
CODE
CHIME
0
#
READY
VOICE
FUNCTION
ADEMCO 5828/5828V
Operation (See NOTE below)
1.
Battery-Powered Operation: When powered by
battery, the keypad activates when any key is
pressed. When the [✱] key is pressed, the keypad
sends a system status request, and displays and/or
annunciates the present status transmitted by the
system.
2.
AC-Powered Operation: When powered by AC, the
keypad remains active at all times. Any change in
system status will cause the display to automatically
turn on (if blank) and display/annunciate the new
status.
If AC power is lost, the keypad will revert to battery-powered
operation until AC power is restored and a new status
request is made ([✱] key).
NOTE: Whether the unit is powered by battery or AC, the
5828/5828V may take up to 5 seconds to display and/or
annunciate the new status after pressing the [✱] key.
WALL MOUNTING
Before mounting the 5828 & 5828V permanently,
determine a good RF location as follows:
If interfacing to a LYNX panel, try communicating
with the panel from different locations.
If interfacing to a VISTA panel, perform a Go/No
Go test from the panel. Refer to the Go/No Go test
mode in the Installation and Setup Guide for the
panel.
Avoid mounting locations on or near large metal objects,
since these can decrease the transmission range or block
transmissions.
Secure the mounting plate to the wall, using proper sized
hardware through the six mounting holes.
Plug the cord from the optional power pack into the
keypad's DC input connector, and route the wires
through the wire guides on the back of the keypad.
Position the keypad over the mounting plate and slide
down, engaging the four retaining clips on the plate with
the receptacles on the keypad.
DESKTOP MOUNTING
For full portability, the keypad may be placed in any conven-
ient, RF-suitable location and operated in its battery-
powered mode, or near an AC outlet to be powered by the
optional Power Pack/Desktop Mounting Kit, ADEMCO P/N
5828DM.
BATTERY INSTALLATION OR REPLACEMENT
CAUTION: Remove the AC/DC power connector from the
keypad (if applicable), before attempting to install or replace
the batteries.
1.
Separate the keypad from its mounting plate by
sliding the keypad up and away from the mounting
plate.
2.
Open the battery compartment door to expose the
batteries.
K0020V3 5/10 Rev. A

Advertisement

loading

Summary of Contents for Honeywell ADEMCO 5828

  • Page 1 INSTALLATION AND SETUP GUIDE GENERAL INFORMATION Operation (See NOTE below) The ADEMCO 5828 and 5828V are wireless, bidirectional, Battery-Powered Operation: When powered by fixed-word, keypads that may be used in conjunction with battery, the keypad activates when any key is LYNX and VISTA series residential control panels.
  • Page 2 Press [3] (Exit Delay) Alternately Install or replace the 3-1.5 Volt AA batteries in the flashes “t3” Press 0-9 in 15 second increments. battery compartment. Always replace all three and value Example: If you press 3, exit delay batteries at once to ensure normal operation of the selected.
  • Page 3 If you select “1” (normally used on LYNX controls) NOTE: If using a LYNX control, and the word “MESSAGE” is announced at the 5828V keypad, it means that there is a Function Key Function message waiting at the control panel, which can only be “Off”...
  • Page 4 FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED. 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747  Copyright 2008 Honeywell International Inc. www.honeywell.com/security ÊK0020V3,Š K0020V3 5/10 Rev. A...

This manual is also suitable for:

Ademco 5828v