International Control Section (Spa8800) - Cisco SPA2102-AN - Single Port Router Administration Manual

Analog telephone adapters
Table of Contents

Advertisement

ATA Voice Field Reference
Line page
Cisco Small Business ATA Administration Guide
Voice tab > Line page >

International Control section (SPA8800)

FXO Port
Impedance
Ring Frequency Min The lower limit of the ring frequency used to detect the ring
SPA To PSTN Gain
Ring Frequency
Max
PSTN To SPA Gain
Ring Validation
Time
Desired impedance of the FXO Port. Choose from {600,
900, 370+620, 270+750||150nF, 220+820||120nF, 370
+ 620 || 310nf, 320 + 1050 || 230nf, 370 + 820 || 110 nf,
275 + 780 || 115nf, 120 + 820 || 110nf, 350 + 1000 ||
210nf, 0 + 900 || 130nf}
The default is 600.
The impedance values for various countries follows:
US—600
EU (UK, Germany, Netherlands, Sweden, Norway, Italy,
Spain, Portugal, Poland, and Denmark)—270+750||150nF
France—270+750||150nF
Australia—220+820||120nF
New Zealand—370+620||310nF
signal.
The default is 10.
dB of digital gain (or attenuation if negative) to be applied
to the signal sent from the SPA to the PSTN side. The range
is -15 to 12.
The default is 0.
The higher limit of the ring frequency used to detect the
ring signal.
The default is 90.
dB of digital gain (or attenuation if negative) to be applied
to the signal sent from the PSTN side to the SPA. The range
is -15 to 12.
The default is 0.
Specify the minimum signal duration required by the
Gateway for recognition as a ring signal. The default is 256
ms.