CARE AND CLEANING

CLEANING THE STEAM WAND AND
FROTHING ATTACHMENT
The Steam Wand and Frothing Attachment
should always be cleaned after frothing milk.
Remove the Frothing Attachment and rinse in
warm tap water. Ensure the two fine steam
holes on either end of the Frothing
Attachment are clear. Use the pin on the
Cleaning Tool to unblock these holes.
Wipe the Steam Wand with a damp cloth,
then with the Steam Wand directed back into
the drip tray, briefly set the Selector Control
to the 'Steam' position and press the Hot
Water button. This will clear any remaining
milk from inside the Steam Wand.
Ensure the Selector Control is in the 'Standby'
position. Press the 'ON/OFF' button to 'OFF',
switch off at the power outlet, unplug the
power cord and allow the machine to cool.
If the Steam Wand remains blocked, use the
pin on the Cleaning Tool to clear the opening.
If the Steam Wand continues to be blocked,
the tip of the Steam Wand can be removed
by using the spanner in the middle of the
Cleaning Tool.
Soak the tip in hot water before using the pin
on the Cleaning Tool to unblock. Replace the
tip back onto the Steam Wand and secure
with the Cleaning Tool.