The purpose of this manual is to provide the user with all the necessary information so that, apart from correct machine use, he or she is able to run it in the most autonomous and safest way. It also includes information on operating the machine and routine maintenance.
The machine can preserve water from possible problems that can occur below the aqueducts, such as infiltrations due to work on the network or breakage, and also from the consequences of keeping water in decantation basins.
The machine has on the rear side no.4 hydraulic connections, for inlet water, permeated water, drain and auxiliary permeate outlet. On the rear side, there is also the electric socket whit fuse. On the front side of the machine, there is the electronic board with display, the ¼ turn rapid filter and the mix valve. N°...
Page 6
From the inlet valve, the water flows to the inlet solenoid valve, on the rear side of the machine, and then through the prefilter. After prefiltering, the water is pumped at high pressure to the osmosis vessel with membranes. The sediment filtration removes suspended solids from water that may damage pump and membranes.
Any use of this device, which has not been stipulated in this manual, will constitute IMPROPER USE, thereby rendering the guarantee null and void. The manufacture WILL NOT be liable for any damages caused by the IMPROPER USE of this device, due to negligence, failure to follow the manual, or permitting unauthorized maintenance personnel to tamper with machine.
WO-04 must be installed by qualified personnel and in compliance with regulations, there must be a tap above (to exclude the equipment from the water system in the case of maintenance interventions), a check valve, water supply pipes above and below the equipment and an electrical outlet.
Page 9
Insert the drainpipe in the nut for about 2 cm and screw the nut on the clamp. Fasten the screw nut and install the check valve with the arrow pointing towards the clasp, as near as possible to the drain.
Insert the feed plug in a 230V 50Hz outlet equipped with efficient grounding. Now the system is able to work. It advisable to run the run for at least a half an hour before drinking it, in order to allow the system to eliminate the substances used to conserve the reverse osmosis membrane.
Page 11
“Alarm Leakage”. Leakage To restart the machine, turn OFF and ON with the key 4.4.2 Display pages When the card is in stand-by mode, the name of the installer is displayed. WO-04 Mikrotec Pressing the key displays the version of software installed in the card.
Page 12
In order to have access to the programming pages, unplug the machine and press Settings Press E key while connecting the feed plug. Subsequently the card will require pressing the key to confirm access to the programming. Scroll the programming pages with the keys.
MAINTENANCE PERSONNEL TASKS The routine maintenance program described in this paragraph must be carried out according to the schedule indicated in order to keep the machine running efficiently and to guarantee the quality of the water treatment. ATTENTION The operations indicated in the following must be carried out by qualified personnel according to the instructions in this manual and only using original spare parts.
Remove the power plug. Empty the expansion tank delivering water to the permeate auxiliary outlet. Remove the side panels and identify the connection of the preload in the tank. With a compressor and a pneumatic gun, bring the preload pressure at 2.5bar Install the panels and connect the power plug.
Apply the glue sealant to calibration nut. 5.5.2 Check operating pressure Install a T fitting and a pressure gauge 0-10 bar (or similar) on the pump outlet line. The operating pressure must be between 6 and 7 bar. 5.5.3 Calibrating conductivity probe Open the electronic board box.
Connect the water pipes of entry, drain and permeated by the machine, at the tank; make a bridge on the low pressure switch connectors. Open a bit the mix valve and turn on the machine and let the solution recirculated for at least 10 minutes.
ELECTRONIC BOARD PROTECTION FUSE REPLACEMENT The machine is equipped with two fuses, one on the electronic board and one on the power socket. 6.2.1 Protection fuse replacement on power socket Remove the fuse compartment under the attack of the power cord.
.2.2 Protection fuse replacement on electronic board Remove the top cover of the machine, accessing the tray card. Remove the support and the cover of the electronic board. Replace the burned fuse with a similar. (Annex V) Mount the electronic board with reverse procedure.
CHECK/REPLACEMENT OF OSMOTIC MEMBRANES A decay of performance rating of 10% per year is considered normal wear for osmotic membranes. Special conditions of entry and/or high consumption may accelerate the clogging of the membranes. Close the mixing valve completely. Supply water and verify scope permeated and conductivity with a reference tool.
Damaged board. Replace the board. Problem: With the display turned on and running, after opening the faucet, the engine will not start. Cause Solution Vane pump blocked. Replace the vane pump.
Page 21
Clogged filter. Replace the filter. Clogged pump. Replace the pump. Clogged membranes. Replace the membranes. It is recommended to install a manometer on the pump outlet to check operating pressure. Problem: Treated water has a bad taste. Cause Solution Exausted filters.
Page 22