Page 1
WO-30-01 Potable water treatment osmosis system for HO.RE.CA. applications. MANUAL use and maintenance 7596043 – MANUAL WO-30-01 ENG_REV. 2...
Page 2
• EN 62233:2008/AC:2010 • EN 55014-1:2006/A1:2009 • EN 55014-1:2006/A2:2011 • EN 55014-2:2015 • EN 61000-3-3:2013 • EN 60335-1:2012/AC:2014 • EN 60335-2-40:2003/A13:2012/AC:2013 22/05/2018 SMEG S.p.A. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 2 -...
MACHINE SANITATION ....................- 18 - TROUBLESHOOTING ..............................20 DISPOSAL ..................................22 ANNEX I – EU LABEL ................................22 ANNEX II - CONNECTIONS OF THE ELECTRONIC BOARD ....................23 ANNEX III – MAINTENANCE LOG............................24 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 3 -...
Page 4
Intentional damage or from negligence, or deriving from the non-compliance with rules and instructions, or due to incorrect connections or unauthorized tampering, invalidate any warranty or liability of the manufacturer. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 4 -...
This symbol Indicates that a visual or in-depth inspection, etc. of the device may be required. INDICATIONS OF DANGER This symbol Indicates General cautions; risk to the operator. This symbol Indicates danger of electrical shock or electrocution. RESTRICTIONS 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 5 -...
This symbol indicates general restrictions. CHARACTERISTICS OF THE DEVICE RECOMMENDED USE WO-30-01 is equipment designed for dish/glass wash machine water treatment. It is able to modify organoleptic and chemical characteristics of potable water, reducing saline content. FORBIDDEN USE ATTENZIONE Use for drinking purposes: IT IS STRICTLY FORBIDDEN to use the equipment for the treatment of non-drinking water.
90-95% the salts present in the raw water. EXTERNAL DIMENSIONS The maximum dimensions do not include hydraulic / electrical connections. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 7 -...
/ or membranes with and loss of water flow rate and quality. WARNING The use of the machine outside the limits indicated is considered IMPROPER USE. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 8 -...
The 3/8" drain pipe must not have any creases or narrowings that could reduce its flow rate. In case of drain clogging, water comes out from the side gaps. 1. FEMALE STRAIGHT 3/8”x1/2” FITTING 2. 3/8” PIPE 3. EN1717 DRAIN ADAPTER 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 9 -...
WARNING After replacing the capillary, set the filter change time in the control unit (see § 4.8) Frequency 50/60 Hz °F <11 12--25 26--35 36--44 HARDNESS °Dh <5 6--15 16--20 21--25 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 10 -...
The device must be calibrated in the installation phase. With WO-30-01, treated water retains about 10-15% of the original saline. In the event of a machine malfunction, this valve allows to exclude the osmosis system and to supply filtered water downstream.
10 minutes before to take water. For longer periods of stop it is recommended to follow the instructions given in the paragraph "set aside" (see §6.4.1). 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 12 -...
It displays the hours spent from the filter change T Total 0000:00 It activates the by-pass EV2 By pass By pass By pass solenoid valve. funct disab enable WARNING WO-30-01 hasn’t automatic by-pass solenoid valve. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 13 -...
Modify the value with the buttons and confirm with button. Setting English Modify the language parameter with the button. Set Language the language with the buttons and confirm with the button. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 14 -...
§6.3) WARNING DO NOT use corrosive products, acids, steel wool or wire brushes to clean the device. DO NOT use low or high pressure jets of water when washing the device. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 15 -...
(*)Special water conditions may require more frequent maintenance. WARNING DO NOT use corrosive products, acids, steel wool or wire brushes to clean the device. DO NOT use low or high pressure jets of water when washing the device. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 16 -...
5 minutes. WARNING THE EXHAUSTED FILTER CARTRIDGE IS QUALIFIED AS SOLID WASTE NOT DANGEROUS AND MUST BE DISPOSED IN ACCORDANCE WITH THE DECISION 2000/532/CE (CODICE CER 15 02 03). 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 17 -...
During the reactivation, which must take place with the tap open, there may be a water leakage. Close the machine by performing the reverse procedure. Switch on the system by pressing the which will be ready for use after 5 minutes. Valve 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 18 -...
The machine is ready to be used. 6.4.1 Set-aside Hydraulically disconnect the system and keep it protected from frost or excessive heat, every 6 months of rest should be repeated a new disinfection cycle. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 19 -...
Open the machine and check for leaks in the hydraulic circuit. Anti-flooding probe Check the position of the probe, if directly in contact with the steel short circuit tray, move it or deoxidize it with a paper towel soaked in alcohol. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 20 -...
Page 21
Check permeate block and non-return valve function. Problem: With the tap open, the machine works intermittently, in fits and starts. Cause Solution High pressure switch set Perform the pressure switch calibration. at too low a pressure. 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 21 -...
Recycling avoids the dispersion of hazardous materials into the municipal waste stream. The crossed-out bin symbol reminds the user not to dispose of this product as unsorted municipal waste. ANNEX I – EU LABEL 7596043 – MANUAL WO-30-01 ENG_REV. 2 - 22 -...