DA-600
PLEASE NOTE THE FOLLOWING WARNING LABEL
(SHOWN IN THE FIGURE.)
REMARK-IF
SAFETYSWITCHES
ARE
OUT
OF
FUNCTION,
THE
LASER
!S ABLE
TO
FUNCTION.
THE LASER LIGHT IS INVISIBLE, AVOID
EXPOSURE.
SO DON'T DISASSEMBLE THE LASER
UNIT,
PLEASE
REPLACE
THE
COM-
PLETE UNIT.
BITTE DAS FOLGENDE WARNSCHILD
BEACHTEN
(IN DER ABBIDUNG GEZEIGT).
BEMERKUNG-
WENN
DIE
SICHERHEITS-
SCHALTER NICHT FUNKTIONSFA-
HIG SIND, IST DER LASER FUNK-
TIONSFAHIG.
DAS
LASERLICHT
IST UNSICHT-
BAR, NICHTS DARUNTERHALTEN.
DIE
LASEREINHEIT
NICHT
AU-
SEINANDERBAUEN,
DIE
KOM-
PLETTE EINHEIT AUSTAUSCHEN.
VEUILLEZ
PRENDRE
NOTE
DES
AVERTISSE-
MENTS
SUIVANTS
ETIQUETTE
(MONTREE
SUR
L'ILLUSTRATION)
REMARQUE-
SI LES CONTACTEURS
DE SECU-
RITE SONT DEREGLES,
LE LASER
PEUT QUAND
MEME
FONCTION-
NER.
LE FAISCEAU
LASER
EST INVISI-
BLE, EVITER DE VOUS Y EXPOSER.
NE PAS DEMONTER LE DISPOSITIF
LASER.
REMPLACER
LE DISPOSI-
TIF COMPLET.
ADJUSTMENT
OF LASER
IS DONE AS FOL-
LOW:
1. CONNECT THE OSCILLOSCOPE
BETWEEN TP.
(TDET) AND
TP. (GND).
2. LOAD
A DISC
IN THE
PLAYER
AND
SET PLAY
MODE.
3. ADJUST
R629
UNTIL THE LEVEL OF THE EFM
SIGNAL ON THE OSCILLOSCOPE IS 700 mv.
SIGNAL
LEVEL IS SUPPOSED
TO BE BETWEEN
500 mV TO 900 mV.
DIE EINSTELLUNG
DES LASERS WIRD WIE
FOLGT DURCHGEFUHRT:
1. DAS OSZILLOSKOP ZWISCHEN TP. (TDET) UND
TP. (GND) ANSCHLIESSEN.
2. EINE DISC IN DEN SPIELER LADEN UND DEN
SPIELER AUF WIEDERGABE SCHALTEN.
3. R629 EINSTELLEN, BIS DER PEGEL DES EFM-
SIGNALS
AUF
DEM
OSZILLOSKOP
700 mV
BETRAGT.
DER
SIGNALPEGEL
SOLLTE
ZWISCHEN
500
mV UND 900 mV LIEGEN.
LE REGLAGE
DU LASER S'EFFECTUE DE LA
MANIERE
SUIVANTE :
1. RACCORDER
UN OSCILLOSCOPE
ENTRE
TP.
(TDET) ET TP. (GND).
2. METTRE
UN DISQUE
EN PLACE DANS
L'AP-
PAREIL
ET METTRE
CELUI-Cl
EN MODE
DE
LECTURE (PLAY).
3. REGLER
R629 JUSQU'A CE QUE LE NIVEAU
DU SIGNAL EFM SUR L'OSCILLOSCOPE SOIT
DE 700 mV.
LE NIVEAU
DU
SIGNAL
DOIT
EN
PRINCIPE
ETRE COMPRIS ENTRE 500 mV ET 900 mV.
FA
at
site
_—
700 ov (EM Signa
Signal EFM
GND
Check that exposed parts are acceptably insulated
from the supply circuit before returning the instru-
ment repaired to the customer.
@ Checking method
Power switch is set to ON.
Next, measure the resistance value between the
both poles of attachement
cup (Power supply
plug) and the input terminal
(outside)
of rear
plate and check that the resistance value is 500
kohms or more,
¢+——— |
INSTRUMENT
Cas
i
(Exposed
part)
O
O
Insulation tester