Installation

Panasonic is not responsible for the accidents or damages caused by failure to
install, inspect and test-run this dryer in accordance with the following methods.

Drain hose connection

- This dryer stores condensed water in the condensed water box by default (please
refer to page 21), or the user can connect a drain hose to drain the condensed water
directly as needed. After connecting the drain hose, please con rm that the drainage
outlet is inserted into the appropriate drainage outlet.
- Please follow the instructions below for operation to prevent water leakage. If you
have any questions, please dial our service hotline for more information.
1.Pull the drain hose out of hole (A).
2.Plug the short hose into (B) pillar and make it xed.
3. After the hose (long drainage hose) in accessories
is connected to the hole (A) and inserted to the
bottom, put the other end of the attached hose into
the drainage outlet.
Attention
- When connecting the drain hose, please make sure that the highest point of the hose
does not exceed the top cover of the product.
- Install the supplied drain hose in such a way that the end is inserted into a oor drain
or other drainage outlet for direct water drainage.
- The end of the drain hose should not be submerged in water; water from the outside
may ow back into the product.
- Water leakage may occur if the pipe is not fully connected to hole (A) or if there is a
loose connection.
11

Post-installation inspection

Level adjustment
- When the four feet stand on the ground, this dryer must be level and balanced
without swaying.
- By adjusting the height of the foot, the level can be adjusted with a level meter.
(Place the level meter in the left and right, front and back positions)
- Adjust the height of foot (4 places) by turning in the direction as shown in the
gure.
※The level meter is not provided as an accessory.
Level meter
Installation con rmation
Con rm the following points:
① Installation site
Whether the product is installed on a at and solid surface?
Whether there is any vibration during operation?
② Adjustment foot assembly
Whether it is securely installed?
③ Power cord connection
Whether separate socket rated 10A and 220-240V
AC is used?
Post-installation test run
Perform the following operations without clothes in the drum.
1. Insert power plug.
2. Close the dryer door.
3. Press the "Power" button to turn on the dryer, then press the "Start/Pause" button.
(Con rm whether there is any abnormal noise, whether the connection is loose and
whether the dryer is operating normally)
Level meter
Adjust upwards
Adjust downwards
12