Husqvarna DXR 95 Operator's Manual page 136

Table of Contents

Advertisement

Available languages

Available languages

Fault code number
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
136
Message in the dis-
play
"Emergency STOP
error Safety stop"
"Machine stop Safety
Stop"
"Remote control error
Safety Stop"
"System pressure
Safety Stop"
"System pressure
Safety Stop"
"System pressure
Safety Stop"
"System pressure
Safety Stop"
"System pressure
Safety Stop"
"Grease level Low"
"Grease level Low"
"Grease temperature
Low"
"Cable error Loss of
function"
"Current limitation
High current detec-
ted"
"Current limitation
Function disabled"
"Current limitation
Function disabled"
Cause
The cable for the Emergency
STOP button is damaged.
The machine stop button is push-
ed on the remote control.
-
-
-
-
-
-
The quantity of grease in the
breaker grease pump is too low.
The temperature is too low and
the breaker grease pump does
not operate correctly.
There is a cable error in the rota-
tion angle sensor.
The extra work light consumes
too much power.
The extra work light consumes
too much power.
The motor is blocked.
Solution
Turn the main switch to ON
and then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the emergency stop but-
ton on the remote control clock-
wise, to disengage the emergen-
cy stop.
Turn the main switch to ON
and then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON
and then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON
and then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON
and then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Speak to Husqvarna service.
Turn the main switch to ON
and then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Fill the breaker grease pump.
Do a check of the grease flow to
the breaker. Apply grease man-
ually if it is necessary.
Do a check of the cable and the
rotation angle sensor.
Disconnect the extra work light
and connect an extra work light
that is within range.
Disconnect the extra work light
and connect an extra work light
that is within range.
Do a check of the motor and the
grease. Disconnect the product
from the power source and con-
nect it again to reset the grease
pump.
1401 - 005 - 11.01.2024