Husqvarna DXR 95 Operator's Manual page 126

Table of Contents

Advertisement

Available languages

Available languages

3. Replace blown fuses. Refer do the decal (C) and
Fuse overview on page 126 .
C
Note:
(A) is Fuse F2-F8, (B) is Fuse F1.
4. Close the cover of the electrical enclosure.
Fuse overview
Fuse table (DXR 95)
Fuse
Current
F1
4 A
F2
10 A
F3
10 A
F4
10 A
F5
3 A
126
B
A
Description of pro-
Voltage
tected components
400/460
T1:AC/DC, KE4:
VAC
Power meter
KE8: Safety PLC
24 VDC
Group 1
KE8: Safety PLC
24 VDC
Group 2
KE8: Safety PLC
24 VDC
Group 3
KE5: Radio Reciev-
24 VDC
er
Fuse
Current
F6
1 A
Fuse table (DXR 145, DXR 275, DXR 305, DXR 315)
Fuse
Current
F1
4 A
F2
15 A
F3
10 A
F4
10 A
F5
10 A
F6
10 A
F7
1 A
F8
3 A
Product software
Speak to your service agent if there is a problem
with the product software or for updates that can be
necessary.
To do after maintenance
1. Do a test operation after maintenance is done.
WARNING:
damage. Incorrectly installed remote
control, cables or hoses can have an
unwanted effect on the movements of
the product.
2. If there is a fault, immediately stop the product. Refer
To stop the product (DXR 95) on page 83 and To
to
stop the product (DXR 145) on page 83 and To stop
the product (DXR 275, DXR 305, DXR 315) on page
84 .
Description of pro-
Voltage
tected components
24 VDC
KE4: Power meter
Description of pro-
Voltage
tected components
400/460
T1:AC/DC, KE4:
VAC
Power meter
24 VDC
M2: Cooling Fan
24 VDC
M3: Oil filling pump
24 VDC
KE1: PLC, Master
KE2: PLC, 1/0 Slave
24 VDC
1
KE3: PLC, 1/0 Slave
24 VDC
2
24 VDC
KE4: Power meter
24 VDC
KE5: Radio receiver
Risk of injury and
1401 - 005 - 11.01.2024

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxr 145Dxr 275Dxr 305Dxr 315

Table of Contents